Single-step centrifugal hematocrit determination on a 10-$ processing device.

نویسندگان

  • L Riegger
  • M Grumann
  • J Steigert
  • S Lutz
  • C P Steinert
  • C Mueller
  • J Viertel
  • O Prucker
  • J Rühe
  • R Zengerle
  • J Ducrée
چکیده

We present a novel concept to process human blood on a spinning polymer disk for the determination of the hematocrit level by simple visual inspection. The microfluidic disk which is spun by a macroscopic drive unit features an upstream metering structure and a downstream blind channel where the centrifugally enforced sedimentation of the blood is performed. The bubble-free priming of the blind channel is governed by centrifugally assisted capillary filling along the sloped hydrophilic side-wall and the lid as well as the special shape of the dead end of the two-layer channel. The hematocrit is indicated at the sharp phase boundary between the plasma and the segregated cellular pellet on a disk-imprinted calibrated scale. This way, we conduct the hematocrit determination of human blood within 5 min at a high degree of linearity (R(2) = 0.999) and at a high accuracy (CV = 4.7%) spanning over the physiological to pathological working range. As all processing steps including the priming, the metering to a defined volume as well as the centrifugation are executed automatically during rotation, the concept is successfully demonstrated in a conventional PC-CDROM drive while delivering the same performance (R(2) = 0.999, CV = 4.3%).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Experimental Investigation into the Effects of High Viscosity and Foamy Oil Rheology on a Centrifugal Pump Performance

This paper presents the effect of high viscosity oil and two-phase foamy-oil flow on the performance of a single stage centrifugal pump. As a part of this, the applicability of a pipe viscometer to determine the foamy oil viscosity is investigated. Unlike previous studies, a sealed fluid tank is used in a closed flow loop to allow conditioning the two-phase mixture to create foamy-oil. Furtherm...

متن کامل

Response of a New Low-Coherence Fabry-Perot Sensor to Hematocrit Levels in Human Blood

In this paper, a low-coherence Fabry-Perot sensor with a spectrally measured signal processing response to the refractive index of liquids is presented. Optical fiber sensors are potentially capable of continuous measuring hematocrit levels in blood. Low-coherence Fabry-Perot interferometric sensors offer a robust solution, where information about the measurand is encoded in the full spectrum o...

متن کامل

Steady-State Performance Characteristics of Photovoltaic System Coupled with a Centrifugal Water Pump

In this article our objective is to obtain steady state characteristics of shunt, series, and separately excited DC motors coupled with a centrifugal water pump supplied through a step-up, step-down, and cuk converter from photovoltaic generator. We assume that there are no storage batteries and, of course, the system must operate on maximum utilization i.e. maximum water must be pumped. It is ...

متن کامل

Steady-State Performance Characteristics of Photovoltaic System Coupled with a Centrifugal Water Pump

In this article our objective is to obtain steady state characteristics of shunt, series, and separately excited DC motors coupled with a centrifugal water pump supplied through a step-up, step-down, and cuk converter from photovoltaic generator. We assume that there are no storage batteries and, of course, the system must operate on maximum utilization i.e. maximum water must be pumped. It is ...

متن کامل

Centrifugal step emulsification applied for absolute quantification of nucleic acids by digital droplet RPA.

Aqueous microdroplets provide miniaturized reaction compartments for numerous chemical, biochemical or pharmaceutical applications. We introduce centrifugal step emulsification for the fast and easy production of monodisperse droplets. Homogenous droplets with pre-selectable diameters in a range from 120 μm to 170 μm were generated with coefficients of variation of 2-4% and zero run-in time or ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biomedical microdevices

دوره 9 6  شماره 

صفحات  -

تاریخ انتشار 2007