Anteroposterior and rotational movement of femur during knee flexion.
نویسندگان
چکیده
This study was designed to analyze anteroposterior and rotational movement of femoral condyles during knee flexion from 15 degrees to 90 degrees using magnetic resonance imaging. After a pilot study, scans were made in 10 healthy male Japanese volunteers. When centers of the circular profiles of posterior femoral condyles were used as reference points, the medial and lateral femoral condyles displaced posteriorly 1.9 +/- 0.8 mm and 2.3 +/- 0.5 mm, respectively (mean +/- standard error). Duplicate examinations on two separate occasions revealed the accuracy of this procedure was in the range of 1 to 2 mm. These results have confirmed that femoral rollback occurs in the unloaded normal knee during flexion from 15 degrees to 90 degrees, but its magnitude is small (2 mm). The results obtained in this in vivo measurement of anteroposterior movement of the femoral condyles have relevance for total knee replacement design.
منابع مشابه
Evaluation of Distal Femoral Rotational Alignment with Spiral CT Scan before Total Knee Arthroplasty (A Study in Iranian Population)
Background: Evaluating the landmarks for rotation of the distal femur is a challenge for orthopedic surgeons. Although the posterior femoral condyle axis is a good landmark for surgeons, the surgical transepicondylar axis may be a better option with the help of preoperative CT scanning. The purpose of this study was to ascertain relationships among the axes’ guiding distal femur rotational ...
متن کاملبررسی تکرارپذیری نیروی عکس العمل زمین حین استفاده از ابزار اعمال اغتشاش اندام تحتانی در حرکت ایستادن روی یک پا
Introduction: The aim of the current study was to measure ground reaction force and center of pressure (COP) during lower extremity perturbation in single leg standing whit knee flexion and extension in healthy subjects, in addition to revealing reliability of the device used for the related perturbation for using another studies, reliability is one of the characteristic of measuring instrumen...
متن کاملA Comparison of Bony Landmarks in the Distal Femur and the Tibial Shaft: Whichlandmark Should Be Used in Total Knee Arthroplasty?
INTRODUCTION: Correct rotational alignment of the femoral component is one of the most important factors for successful total knee arthroplasty. The rotational position of the femoral component can be determined using bony landmarks, such as the transepicondylar axis, the posterior condylar axis, or the anteroposterior (AP) axis (Whiteside’s line). Rotational alignment of the femoral component ...
متن کاملTibiofemoral movement 1: the shapes and relative movements of the femur and tibia in the unloaded cadaver knee.
In six unloaded cadaver knees we used MRI to determine the shapes of the articular surfaces and their relative movements. These were confirmed by dissection. Medially, the femoral condyle in sagittal section is composed of the arcs of two circles and that of the tibia of two angled flats. The anterior facets articulate in extension. At about 20 degrees the femur 'rocks' to articulate through th...
متن کاملA kinematic comparison of fixed- and mobile-bearing knee replacements.
Mobile-bearing posterior-stabilised knee replacements have been developed as an alternative to the standard fixed- and mobile-bearing designs. However, little is known about the in vivo kinematics of this new group of implants. We investigated 31 patients who had undergone a total knee replacement with a similar prosthetic design but with three different options: fixed-bearing posterior cruciat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical orthopaedics and related research
دوره 362 شماره
صفحات -
تاریخ انتشار 1999