Ultrasound imaging velocimetry of the human vitreous.

نویسندگان

  • Tommaso Rossi
  • Giorgio Querzoli
  • Giacomo Pasqualitto
  • Mario Iossa
  • Luca Placentino
  • Rodolfo Repetto
  • Alessandro Stocchino
  • Guido Ripandelli
چکیده

Knowledge of vitreous motion in response to saccades is a prerequisite for understanding vitreous rheology. Purpose of present paper is to introduce Ultrasound Image Velocimetry of the human eye, measure scleral and vitreous velocity fields and test the reproducibility of the proposed technique. Twelve patients with varying diagnosis underwent Ocular Dynamic Ultrasound; scleral angular velocity (V(S)) was measured by 2 different operators and reproducibility calculated. Squared velocity of the vitreous (E), which is representative of kinetic energy per unit mass, was computed from velocity. The time evolution of the energy of the vitreous was described by its spatial average (E(S)), whereas spatial distribution was described by its time average (E(T)). Peak and average E(S), the ratio K(p) of the peak of the spatially averaged kinetic energy per unit mass to the maximum squared scleral angular velocity, vitreous motion onset time (T(O)) and vitreous motion decay time (T(D)) were also defined. Inter-operator reproducibility coefficient was 0.043 and correlation between operators was significant. V(S), peak and average E(S), K(p) ratio and T(D) differed among patients but not among operators. V(S) correlated with E(S) and T(D). E(S) and T(D) but not V(S), were significantly different in patients with Posterior Vitreous Detachment. Patients with retinal detachment showed significantly higher V(S) and E(S). K(p) was inversely correlated to age and refraction. Measures proved accurate and reproducible. E is related to V(S), retinal traction and mechanical stimulation. Identified variables varied with age, refraction pathologic conditions.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pulse-encoded ultrasound imaging of the vitreous with an annular array.

The vitreous body is nearly transparent both optically and ultrasonically. Conventional 10- to 12-MHz diagnostic ultrasound can detect vitreous inhomogeneities at high gain settings, but has limited resolution and sensitivity, especially outside the fixed focal zone near the retina. To improve visualization of faint intravitreal fluid/gel interfaces, the authors fabricated a spherically curved ...

متن کامل

Vitreous image enhancement in an ophthalmic sonographic imaging system using Golay coded excitation.

OBJECTIVE The purpose of this study was to enhance the weak echoes of low reflective vitreous opacities on ophthalmic sonography. METHODS A simulation study on a vitreous enhancement algorithm based on coded excitation was performed, with the analysis of the transmit efficiency and motion effects. On the basis of the simulation results, we have implemented a 10-MHz B-mode experimental sonogra...

متن کامل

Design, Evaluation and Prototyping of a New Robotic Mechanism for Ultrasound Imaging

This paper presents a new robotic mechanism for ultrasound imaging. The device is placed on a patient's body by an operator, and an ultrasound expert controls the motions of the device to obtain ultrasound images. The paper focuses on the robotic mechanism that performs ultrasound imaging. The design of the mechanism is based on two approaches to produce center of motion for an ultrasound probe...

متن کامل

Real-time ultrasound elastographic imaging of ocular and periocular tissues: a feasibility study.

BACKGROUND AND OBJECTIVE This study examines the value of ultrasound elastography for the examination of ocular and periocular structures. SUBJECTS AND METHODS Five patients, aged 22 to 75 years, who each had one blind eye were included. Patients underwent ultrasound elastography of their blind eye and periocular tissues using a 7-13 MHz probe. Strain grayscale and color-coded elastographic m...

متن کامل

Prediction of Neonatal Outcome by Umbilical Artery Velocimetry in Intrauterine Growth Restriction: A Study in Western Nepal

The introduction of Doppler velocimetry to obstetrics offered a noninvasive and safe imaging modality of indirectly assessing the fetal and uteroplacental circulation. Obstetric Doppler ultrasound plays an important role in detecting Intra Uterine Growth Restriction (IUGR). The early diagnosis of IUGR with the help of abnormal flow patterns in umbilical, uterine and middle cerebral arteries usi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Experimental eye research

دوره 99  شماره 

صفحات  -

تاریخ انتشار 2012