Comparison of laser speckle contrast imaging with laser Doppler for assessing microvascular function.

نویسندگان

  • Garry A Tew
  • Markos Klonizakis
  • Helen Crank
  • J David Briers
  • Gary J Hodges
چکیده

OBJECTIVE To compare the inter-day reproducibility of post-occlusive reactive hyperaemia (PORH) and sympathetic vasomotor reflexes assessed by single-point laser Doppler flowmetry (SP-LDF), integrating-probe LDF (IP-LDF) and laser speckle contrast imaging (LSCI), and the spatial variability of PORH assessed by IP-LDF and LSCI. We also evaluated the relationship between IP-LDF and LSCI perfusion values across a broad range of skin blood flows. METHODS Eighteen healthy adults (50% male, age 27 ± 4 years) participated in this study. Using SP-LDF, IP-LDF and LSCI, indices of skin blood flow were measured on the forearm during PORH (1-, 5- and 10-min occlusions) and on the finger pad during inspiratory gasp and cold pressor tests. These tests were repeated 3-7 days later. Data were converted to cutaneous vascular conductance (CVC; laser Doppler flow/mean arterial pressure) and expressed as absolute and relative changes from pre-stimulus CVC (ΔCVC(ABS) and ΔCVC(REL), respectively), as well as normalised to peak CVC for the PORH tests. Reproducibility was expressed as within-subjects coefficients of variation (CV, in %) and intraclass correlation coefficients. RESULTS The reproducibility of PORH on the forearm was poorer when assessed with SP-LDF and IP-LDF compared to LSCI (e.g., CV for 5-min PORH ΔCVC(ABS)=35%, 27% and 19%, respectively), with no superior method of data expression. In contrast, the reproducibility of the inspiratory gasp and cold pressor test responses on the finger pad were better with SP-LDF and IP-LDF compared to LSCI (e.g., CV for inspiratory gasp ΔCVC(REL)=13%, 7% and 19%, respectively). The spatial variability of PORH responses was poorer with IP-LDF compared to LSCI (e.g., CV ranging 11-35% versus 3-16%, respectively). The association between simultaneous LSCI and IP-LDF perfusion values was non-linear. CONCLUSION The reproducibility of cutaneous PORH was better when assessed with LSCI compared to SP-LDF and IP-LDF; probably due to measuring larger skin areas (lower inter-site variability). However, when measuring sympathetic vasomotor reflexes on the finger pad, reproducibility was better with SP-LDF and IP-LDF, perhaps due to the high sensitivity of LSCI to changes in skin blood flow at low levels.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A novel effective method for the assessment of microvascular function in male patients with coronary artery disease: a pilot study using laser speckle contrast imaging

Evaluation of microvascular endothelial function is essential for investigating the pathophysiology and treatment of cardiovascular and metabolic diseases. Although laser speckle contrast imaging technology is well accepted as a noninvasive methodology for assessing microvascular endothelial function, it has never been used to compare male patients with coronary artery disease with male age-mat...

متن کامل

Advances in Cardiovascular Imaging Assessment of Skin Microvascular Function and Dysfunction With Laser Speckle Contrast Imaging

In recent years, skin microcirculation has been considered an easily accessible and potentially representative vascular bed to evaluate and understand the mechanisms of microvascular function and dysfunction.1–3 Vascular dysfunction (including impaired endothelium-dependent vasodilation) induced by different pathologies is evident in the cutaneous circulation.4–7 It has been suggested that the ...

متن کامل

Assessment of skin microvascular function and dysfunction with laser speckle contrast imaging.

In recent years, skin microcirculation has been considered an easily accessible and potentially representative vascular bed to evaluate and understand the mechanisms of microvascular function and dysfunction.1–3 Vascular dysfunction (including impaired endothelium-dependent vasodilation) induced by different pathologies is evident in the cutaneous circulation.4–7 It has been suggested that the ...

متن کامل

Multiscale Compression Entropy of Microvascular Blood FlowSignals: Comparison of Results from Laser Speckle Contrastand Laser Doppler Flowmetry Data in Healthy Subjects

Microvascular perfusion is commonly used to study the peripheral cardiovascular system. Microvascular blood flow can be continuously and non-invasively monitored with laser speckle contrast imaging (LSCI) or with laser Doppler flowmetry (LDF). These two optical-based techniques give perfusion values in arbitrary units. Our goal is to better understand the perfusion time series given by each tec...

متن کامل

Simultaneous measurement of water flow velocity with fluorescent and speckle imaging technique

The average velocity of water flow has been simultaneously measured with fluorescent and speckle imaging methods. The measured velocities with two methods are in good agreement with each other and it confirms that the speckle imaging method can be used as a confident method to measure the velocity of water flow in a dry leaf. Also the velocity of water flow through thick and thin xylems of a le...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Microvascular research

دوره 82 3  شماره 

صفحات  -

تاریخ انتشار 2011