Real-Time Data Acquisition and Control System for A Neutron Polarisation Analysis Spectrometer (LONGPOL)

نویسنده

  • Y. Fei
چکیده

One of the key features of LONGPOL, the neutron polarisation analysis instrument running in ANSTO, Australia, is the development of a real-time data acquisition and control system. The system provides separation of neutron spin-flip and nonspin-flip events and provides energy analysis through the timeof-flight method. This system is composed of five DSP boards, one is the master board, and the others are slave boards. A firmware has been developed to drive the complete system. A pseudo-random sequence is generated with a minimum channel width of 0.156 μsec to control the neutron flipper, and the neutron counts from eight detectors, binned according to the sequence, are stored in the built-in RAM in real-time. The data are transferred to a host computer for the cross-correlation, and analysed by the LONGPOL DIF program.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fully digital data acquisition system for the neutron time-of-flight spectrometer TOFOR at JET.

A prototype of a fully digital data acquisition system based on 1 Gsps 12 bit digitizers for the TOFOR fusion neutron spectrometer at JET is assessed. The prototype system enables the use of geometry-based background discrimination techniques, which are modeled, evaluated, and compared to experimental data. The experimental results are in line wit...

متن کامل

Simulation of a Neutron Detector for Real Time Imaging Applications

Monte Carlo Method is used to simulate a double layer gadolinium-amorphous silicon thermal neutron detector. The detector fabricated in pixel array configuration has various applications including neutron imaging. According to the simulation results, a detector consisting of a gadolinium (Gd) film with thickness of 2-4 ~m, sandwiched properly with two layers of sufficiently thick (-30 ?µm) hydr...

متن کامل

The compact neutron spectrometer at ASDEX Upgrade.

The first neutron spectrometer of ASDEX Upgrade (AUG) was installed in November 2008. It is a compact neutron spectrometer (CNS) based on a BC501A liquid scintillating detector, which can simultaneously measure 2.45-MeV and 14-MeV neutrons emitted from deuterium (D) plasmas and γ radiation. The scintillating detector is coupled to a digital pulse shape discrimination data acquisition (DPSD) sys...

متن کامل

Radiation Effects on the On-line Monitoring System of a Hadrontherapy Center

Introduction Today, there is a growing interest in the use of hadrontherapy as an advanced radiotherapy technique. Hadrontherapy is considered a promising tool for cancer treatment, given its high radiobiological effectiveness and high accuracy of dose deposition due to the physical properties of hadrons. However, new radiation modalities of dose delivery and on-line beam monitoring play crucia...

متن کامل

Digital Data Acquisition System for Time of Flight Neutron Beam Measurements

Rensselaer Polytechnic Institute: Gaerttner LINAC Laboratory, Troy, New York, 12180, [email protected] INTRODUCTION A system for neutron scattering measurements is under development at the RPI LINAC [1]. The system is design to provide additional differential scattering data to improve upon the currently available cross section data. The system is designed to work in the energy range of 0.2-20 MeV...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000