Biomechanical comparison of intact lumbar lamb spine and endoscopic discectomized lamb spine.

نویسندگان

  • Ahmet Karakaşlı
  • Didem Venüs Yıldız
  • Erdem Kumtepe
  • Ceren Kızmazoğlu
  • Hasan Havıtçıoğlu
چکیده

OBJECTIVES This study aims to perform a biomechanical comparison of changes on motion segments after minimally invasive percutaneous endoscopically discectomized and intact spine and to investigate the effects of endoscopic discectomy on the lumbar spine of the lamb. MATERIALS AND METHODS Ten fresh-frozen lamb spines were used in this study. Percutaneous endoscopic discectomy was performed on each spine at L4-L5 level. The biomechanical tests for both intact spine and endoscopically discectomized spine were performed by using axial compression testing machine. The axial compression was applied to all specimens with a loading speed of 5 mm/min. 8400 N/mm moment was applied to each specimen to achieve flexion and extension motions, right and left bending through a specially designed fixture. RESULTS In axial compression and flexion tests, the specimens were more stable based on displacement values. The displacement values of discected spines were closer to the values of intact specimens. Comparing both groups, only displacement values of the left-bending anteroposterior test were significant (p≤0.05). CONCLUSION Percutaneous transforaminal endoscopic discectomy (PTED) has no biomechanical and clinical disadvantages. Endoscopic discectomy has also no stability disadvantages. Only anteroposterior displacement values of left bending test were statistically significant. We consider that the reason for such results were due to the fact that PTED was performed on the left side of all specimens.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mechanical Instability on Lumbar Spine at the Adjacent and Subjacent Segment after Rigid Fixation

To investigate the effect of PLIF and after rigid fixation on adjacent segment and subjacent mechanical instability moreover under loading adjacent and subjacent segment mechanical behavior. Eleven fresh-frozen lamb lumbar spines (Sacrum-T12) were loaded, in axial, flexion-extension, right-left bending directions. All specimens were tested intact and after implantation with posterior pedicle sc...

متن کامل

Comparison of Supplementary Posterior Fixations for Two-Level ALIF with Stand-Alone Cages

INTRODUCTION: Structural cages have been widely used in recent years to maintain motion segment height and stability in anterior lumbar interbody fusion (ALIF). High rate of clinical success and radiological fusion rate have been reported following single-level fusion using these cages. However, many biomechanical studies report insufficient stability, especially with extension loading. Posteri...

متن کامل

Biomechanically Constrained Ultrasound to Computed Tomography Registration of the Lumbar Spine

Spinal injections for back-pain management are frequently carried out in hospitals and radiological clinics. Currently, these procedures are performed under fluoroscopy or CT guidance in specialized interventional radiology facilities, and thus incur a major financial burden on the healthcare system. Additionally, the current practice exposes patients and surgeons to X-ray radiation. The use of...

متن کامل

Congenital lumbar vertebrae agenesis in a lamb

Congenital agenesis of lumbar vertebrae was diagnosed in a day-old female lamb based on radiology and clinical examinations. There was no neurological deficit in hindlimb and forelimb associated with standing disability. Radiography of the abdominal region revealed absence of lumbar vertebrae. Necropsy confirmed clinical and radiographic results. No other anomaly or agenesis was seen macroscopi...

متن کامل

Adjacent segment motion after a simulated lumbar fusion in different sagittal alignments: a biomechanical analysis.

STUDY DESIGN An in vitro biomechanical study of adjacent segment motion (at L3-L4 and L5-S1) after a simulated lumbar interbody fusion of L4-L5 in different sagittal alignments was carried out. OBJECTIVES To test the hypothesis that an L4-L5 fixation in different sagittal alignments causes increased angular motion at the adjacent levels (L3-L4 and L5-S1) in comparison with the intact spine. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Eklem hastaliklari ve cerrahisi = Joint diseases & related surgery

دوره 24 1  شماره 

صفحات  -

تاریخ انتشار 2013