Characterization of sensitivity and specificity in leaky droplet-based assays.

نویسندگان

  • Yunhan Chen
  • Adi Wijaya Gani
  • Sindy K Y Tang
چکیده

This paper uses numerical methods to characterize the crosstalk of small fluorescent molecules and molecular probes among aqueous droplets immersed in a continuous phase of hydrocarbons or fluorocarbons in microfluidic systems. Droplet-based biochemical assays rely on the reagents to remain isolated in individual droplets. It has been observed, however, that small and hydrophobic fluorescent molecules can diffuse across the droplet boundary into other drops. The contents among droplets become mixed and homogenized over time. Such cross-contamination can have detrimental effects on the accuracy of droplet-based assays, especially those using fluorescent molecules and the corresponding number of fluorescent droplets for a quantitative readout. This work examines the competing dynamics of the generation of fluorescent molecules in "positive" drops (in response to the presence of molecules or cells of interest), against its leakage into "negative" drops, where such molecules or cells of interest are absent. In ideal droplet assays, the signal-to-noise ratio (SNR)--defined as the fluorescence signal from a positive drop to that from a negative drop--would increase and saturate with time. In a leaky droplet assay, the SNR tends to decay with time. Under certain conditions, however, the SNR from a leaky droplet assay could increase and reach a maximum value before it starts to diminish. This maximum value can be estimated from a dimensionless number relating the rate of leakage relative to the rate of generation of fluorescence signal in the drops. Beyond the time when the SNR peaks, the SNR value, as well as the accuracy of the leaky droplet assay continues to degrade. In the absence of immediate experimental remedies to completely eliminate the crosstalk of molecules among drops, performing detection at the optimal time point becomes critical to minimize errors in leaky droplet assays.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Study of leaky dielectric droplet behavior under an electric field: effect of viscosity and electric conductivity ratios

In this research, hydrodynamic behavior of a leaky dielectric droplet under an electric field is simulated. The level set method is used for interface tracking and the ghost fluid method is used for modeling discontinuous quantities at interface. Using Taylor’s leaky dielectric model, electric field and electric force at the interface is calculated. Simulation results show the droplet deformati...

متن کامل

PCR-based detection of Theileria infection and molecular characterization of Tams1 T. annulata vaccine strain

In order to develop a method for detecting and identification of Theileria annulata, the specific primers from the major merozoite-piroplasm surface antigen sequence of Theileria (Tams1) were used to detect the T. annulata by nested-PCR technique. The assay provides a valuable tool for the identification of Theileria annulata directly from clinical samples and enables determination of the infec...

متن کامل

Molecular detection of pathogenic leptospiral serovars by PCR, based on lipL21 gene

Leptospirosis is a zoonotic disease with global distribution that caused by pathogenic spirochetes of the genus Leptospira. Accurate diagnosis for differentiation of leptospirosis from other pyrogenic infections prevailing in the same locality and is imperative for proper treatment. Therefore a molecular diagnostic test with high specificity and sensitivity such as PCR is essential. Gene encodi...

متن کامل

Assessment of a rapid immunochromatographic assay for the detection of avian influenza viruses

Rapid spreading of the low pathogenic avian influenza virus (AIV) caused by the H9N2 subtype and the highly pathogenic AIV caused by H5N1 have caused serious economic losses in the poultry industries of Asia. Therefore, the early detection of AIVs is crucial for the control of the disease. In the present study, the applicability of a rapid immunochromatographic (RIC) assay, which specifically d...

متن کامل

ارزیابی هزینه- اثربخشی روشهای اندازهگیری HbA1C در ایران

Background: Diabetic patients need to be followed for glycemic index regularly and HbA1c test is one of the most important biochemical markers for patient monitoring.  HbA1c should be standardized based on international standards, but using internationally accepted assays are expensive. This study aimed to evaluate cost effectiveness of different assays which are currently used in Iran. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Lab on a chip

دوره 12 23  شماره 

صفحات  -

تاریخ انتشار 2012