GRE T2∗-Weighted MRI: Principles and Clinical Applications

نویسندگان

  • Meng Yue Tang
  • Tian Wu Chen
  • Xiao Ming Zhang
  • Xiao Hua Huang
چکیده

The sequence of a multiecho gradient recalled echo (GRE) T2*-weighted imaging (T2*WI) is a relatively new magnetic resonance imaging (MRI) technique. In contrast to T2 relaxation, which acquires a spin echo signal, T2* relaxation acquires a gradient echo signal. The sequence of a GRE T2*WI requires high uniformity of the magnetic field. GRE T2*WI can detect the smallest changes in uniformity in the magnetic field and can improve the rate of small lesion detection. In addition, the T2* value can indirectly reflect changes in tissue biochemical components. Moreover, it can be used for the early diagnosis and quantitative diagnosis of some diseases. This paper reviews the principles and clinical applications as well as the advantages and disadvantages of GRE T2*WI.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Microbleeding in the head of caudate nuclei of a patient with hypertension.

headache for one month. MRI revealed a small expanded nodule in the head of the right caudate nuclei (Fig. 1). It was hyper intense on both T1(left) and T2-weighted (right) images. Bleeding was suspected, however, other causes including tumor could not be excluded at this time. Subsequent angiography showed no abnormality. Her symptom disappeared gradually without any treatment. Four weeks late...

متن کامل

Non-invasive quantification of liver fat content by different Gradient Echo MRI sequences in patients with Non-Alcoholic Fatty Liver Disease (NAFLD)

Introduction: Non-invasive quantification of liver fat by Gradient echo (GRE) Technique is an interesting issue in quantitative MRI. Despite the numerous advantages of this technique, fat measurement maybe biased by confounding and effects. The aim of this study was to evaluate the GRE pulse sequences with different   and  weighting for liver fat quantification in patients with...

متن کامل

Susceptibility-weighted imaging is more reliable than T2*-weighted gradient-recalled echo MRI for detecting microbleeds.

BACKGROUND AND PURPOSE We investigated the sensitivity and reliability of MRI susceptibility-weighted imaging (SWI) compared with routine MRI T2*-weighted gradient-recalled echo (GRE) for cerebral microbleed (CMB) detection. METHODS We used data from a prospective study of cerebral amyloid angiopathy (n=9; mean age, 71±8.3) and healthy non-cerebral amyloid angiopathy controls (n=22; mean age,...

متن کامل

WEEKDAY EDUCATIONAL COURSE Everything You Wanted to Know about Magnetic Susceptibility & Why It Is Important

Gradient Recalled Echo (GRE) based MR imaging techniques have wide applications in MRI. Due to the absence of refocusing RF pulses GRE sequences are fast and since low flip angles are usually applied, GRE sequences have low specific absorption rate, hence are particularly well suited for high field MRI. While MR signal generated from GRE techniques is complex, most traditional applications rely...

متن کامل

Susceptibility-weighted imaging in familial cerebral cavernous malformations.

A 59-year-old man with a family history of cerebral cavernous malformations (CCM) presented with focal seizures. T2*-weighted gradient echo (GRE) images showed multiple lesions consistent with cavernous malformations (figure 1). Susceptibility-weighted images (SWI) detected nearly triple the number of lesions than were seen with the GRE sequence (figure 2). SWI is a relatively new MRI technique...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2014  شماره 

صفحات  -

تاریخ انتشار 2014