Isometric muscle length-tension curves do not predict angle-torque curves of human wrist in continuous active movements.

نویسندگان

  • D M Gillard
  • S Yakovenko
  • T Cameron
  • A Prochazka
چکیده

In this study we tested the hypothesis that during steady contractions of human wrist extensors or flexors, the torque-angle relationship during movements imposed about the wrist is predicted by the classical isometric muscle length-tension curve, with ascending, descending and ascending limbs. Angle-torque relationships were measured during steady muscle activation (10% of maximal voluntary contraction: MVC), elicited either by electrical stimulation or voluntary regulation of the electromyogram (EMG). Flexion-extension movements of constant speed (+/-10 degrees /s) were imposed on the subjects' hands with a servo actuator, either through the full physiological range of motion +/-50 degrees, or through +/-10 degrees. During extensor contractions, angle-torque curves in +/-50 degrees movements had ascending, descending and ascending limbs, as in isometric contractions. However, in +/-10 degrees movements, torque always increased with increasing muscle length and decreased with decreasing length, even over angles corresponding to the descending limb of isometric curves. For flexor activation, angle-torque curves had similar properties, though descending limbs were less obvious or absent. During imposed movements, hysteresis was observed in the angle-torque curves. This was attributed to non-linearities of the active muscles. Hysteresis reached a maximum at intermediate wrist angles and declined at maximal muscle length, contradicting the recent hypothesis that sarcomere non-uniformity is responsible for the hysteresis. We conclude that the classical isometric length-tension curve, with its prominent descending limb, does not predict angle-torque curves of human wrist muscles in continuous movements. A more appropriate model is one in which stiffness about the wrist is always positive and hysteresis is a significant factor.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A comparison of two Hill-type skeletal muscle models on the construction of medial gastrocnemius length-tension curves in humans in vivo.

Human length-tension curves are traditionally constructed using a model that assumes passive tension does not change during contraction (model A) even though the animal literature suggests that passive tension can decrease (model B). The study's aims were threefold: 1) measure differences in human medial gastrocnemius length-tension curves using model A vs. model B, 2) test the reliability of u...

متن کامل

Human wrist motors: biomechanical design and application to tendon transfers.

Moment arm, muscle architecture, and tendon compliance in cadaveric human forearms were determined and used to model the wrist torque-joint angle relation (i.e. wrist torque profile). Instantaneous moment arms were calculated by differentiating tendon excursion with respect to joint rotation. Maximum isometric tension of each wrist muscle-tendon unit was predicted based on muscle physiological ...

متن کامل

The Length Dependency of Force-frequency Characteristics of Human Tibialis Anterior Muscle

For practical purposes of FES, a better understanding of properties of human muscles, stimulated via surface electrodes, is necessary. With a long term aim of improving control of muscle output, the purpose of this study was to investigate the force-frequency relationships as a function of muscle length in human skeletal muscles under isometric conditions. In order to asses the influence of len...

متن کامل

Effects of strength training aided by electrical stimulation on wrist muscle characteristics and hand function of children with hemiplegic cerebral palsy.

Nine children with spastic hemiplegic cerebral palsy underwent 24 sessions of wrist muscles strengthening in the extended wrist range aided by electrostimulation. Isometric strength of flexors and extensors was registered in three wrist positions (30 degrees of flexion, neutral, and 30 degrees of extension) to infer on angle-torque curves. Passive stiffness of wrist flexors and wrist flexion an...

متن کامل

Task complexity and maximal isometric strength gains through motor learning

This study compared the effects of a simple versus complex contraction pattern on the acquisition, retention, and transfer of maximal isometric strength gains and reductions in force variability. A control group (N = 12) performed simple isometric contractions of the wrist flexors. An experimental group (N = 12) performed complex proprioceptive neuromuscular facilitation (PNF) contractions cons...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of biomechanics

دوره 33 11  شماره 

صفحات  -

تاریخ انتشار 2000