Pii: S0730-725x(02)00563-5

نویسندگان

  • Christian Windischberger
  • Herbert Langenberger
  • Thomas Sycha
  • Edda M. Tschernko
  • Gabriele Fuchsjäger-Mayerl
  • Leopold Schmetterer
  • Ewald Moser
چکیده

BOLD-based functional MRI (fMRI) can be used to explicitly measure hemodynamic aspects and functions of human neuro-physiology. As fMRI measures changes in regional cerebral blood flow and volume as well as blood oxygenation, rather than neuronal brain activity directly, other processes that may change the above parameters have to be examined closely to assess sensitivity and specificity of fMRI results. Physiological processes that can cause artifacts include cardiac action, breathing and vasomotion. Although there has been substantial research on physiological artifacts and appropriate compensation methods, controversy still remains on the mechanisms that cause the fMRI signal fluctuations. Respiratory-correlated fluctuations may either be induced by changes of the magnetic field homogeneity due to moving organs, intra-thoracic pressure differences, respiration-dependent vasodilation or oxygenation differences. The aim of this study was to characterize the impact of different breathing patterns by varying respiration frequency and/or tidal volume on EPI time courses of the resting human brain. The amount of respiration-related oscillations during three respiration patterns was quantified, and statistically significant differences were obtained in white matter only: p 0.03 between 6 vs. 12 ml/kg body weight end tidal volume at a respiration frequency of 15/min, p 0.03 between 12 vs. 6 ml/kg body weight and 15 vs. 10 respiration cycles/min. There was no significant difference between 15 vs. 10 respiration cycles/min at an end tidal volume of 6 ml/kg body weight (p 0.917). In addition, the respiration-affected brain regions were very similar with EPI readout in the a-p and l-r direction. Based on our results and published literature we hypothesize that venous oxygenation oscillations due to changing intra-thoracic pressure represent a major factor for respiration-related signal fluctuations and increase significantly with increasing end tidal volume in white matter only. © 2002 Elsevier Science Inc. All rights reserved.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pii: S0730-725x(00)00154-5

We describe an MR-compatible ventilator that is computer controlled to generate a variety of breathing patterns, to minimize image degrading effects of breathing motion, and to support delivery of gas anesthesia and experimental inhalational gases. A key feature of this ventilator is the breathing valve that attaches directly to the endotracheal tube to reduce dead volume and allows independent...

متن کامل

Pii: S0730-725x(00)00153-3

In this study the noise sensitivity of various anisotropy indices has been investigated by Monte-Carlo computer simulations and magnetic resonance imaging (MRI) measurements in a phantom and 5 healthy volunteers. Particularly, we compared the noise performance of indices defined solely in terms of eigenvalues and those based on both the eigenvalues and eigenvectors. It is found that anisotropy ...

متن کامل

Pii: S0730-725x(02)00485-x

The influence of Gd-DTPA on T1-weighted (T1W) proton MR spectra has been investigated in 19 patients with histologically verified low (n 13) or high-grade (n 6) gliomas. Repeat measurements were performed on 9 patients (7 low-grade and 2 high-grade), with 28 examinations performed in total. Comparison of spectra obtained before and after 0.2 mmol/kg Gd-DTPA showed contrast agent induced broaden...

متن کامل

Pii: S0730-725x(02)00516-7

Functional MRI (fMRI) can detect blood oxygenation level dependent (BOLD) hemodynamic responses secondary to neuronal activity. The most commonly used method for detecting fMRI signals is the gradient-echo echo-planar imaging (EPI) technique because of its sensitivity and speed. However, it is generally believed that a significant portion of these signals arises from large veins, with additiona...

متن کامل

Pii: S0730-725x(02)00508-8

A semi-automated method is described for segmenting the cerebellum from T1-weighted 3-dimensional magnetic resonance imaging scans of adult controls and patients. The method relies on prior knowledge involving a user-defined template as a guide to aid the segmentation of the cerebellum. As the gray and white matter intensity distribution in the cerebellum has a complex pattern, texture informat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002