Comparing dynamic contour tonometry to Goldmann and hand-held tonometry in normal, ocular hypertension, and glaucoma populations.
نویسندگان
چکیده
We prospectively compared dynamic contour tonometry (DCT) to Goldmann (GAT) and hand-held tonometry (HHT) in normal, ocular hypertension, and glaucoma populations. Both measurements were made on each patient within a 5-minute period during routine office exams over 4 months. While DCT is in good overall agreement with GAT and HTT, there is some systematic deviation at different pressure ranges in normal, ocular hypertension, and glaucoma populations.
منابع مشابه
Correlation between diurnal variation of intraocular pressure, ocular pulse amplitude and corneal structural properties.
PURPOSE The purpose of this study was to evaluate the fluctuation of intraocular pressure measurements obtained by Goldmann applanation tonometry, dynamic contour tonometry, and corneal compensated non-contact tonometry during office hours in glaucoma and healthy participants. This study also aims at correlating the intraocular pressure fluctuations with fluctuations of corneal hysteresis, cent...
متن کاملIntraocular pressure and ocular pulse amplitude using dynamic contour tonometry and contact lens tonometry
BACKGROUND The new Ocular Dynamic Contour Tonometer (DCT), investigational device supplied by SMT (Swiss Microtechnology AG, Switzerland) allows simultaneous recording of intraocular pressure (IOP) and ocular pulse amplitude (OPA). It was the aim of this study to compare the IOP results of this new device with Goldmann tonometry. Furthermore, IOP and OPA measured with the new slitlamp-mounted D...
متن کاملمقایسه دقت اندازه گیری فشار داخل چشم با سه تونومتر پالس ایر، تونوپن و گلدمن
Introduction & Objective: The measurement of Intraocular pressure (IOP) is very important not only in the diagnosis and management of glaucomatous conditions but also in any ophthalmologic examination. So this study was designed to compare the results of noncontact pulsair and tononpen tonometry with goldmann known as gold standard method. Materials & Methods: In this cross sectional study o...
متن کاملCorrelation between ocular perfusion pressure and ocular pulse amplitude in glaucoma, ocular hypertension, and normal eyes
BACKGROUND The purpose of this study was to investigate the correlation between ocular perfusion pressure and ocular pulse amplitude in glaucoma, ocular hypertension, and normal eyes. METHODS Ninety eyes from 90 patients were included. Thirty patients had been recently diagnosed with glaucoma and had no previous history of treatment for ocular hypotension, 30 had elevated intraocular pressure...
متن کاملReview on Dynamic Contour Tonometry and Ocular Pulse Amplitude.
Intraocular pressure (IOP) measurement is the cornerstone of the management of glaucoma patients. The gold standard for assessing IOP is Goldmann applanation tonometry (GAT). Recently, the dynamic contour tonometer (DCT) has become available. While both devices provide reliable IOP measurements, the results are not interchangeable. DCT has the advantage of measuring an additional parameter: ocu...