Exhaled breath condensate pH assays are not influenced by oral ammonia.

نویسندگان

  • K Wells
  • J Vaughan
  • T N Pajewski
  • S Hom
  • L Ngamtrakulpanit
  • A Smith
  • A Nguyen
  • R Turner
  • J Hunt
چکیده

BACKGROUND Measurement of pH in exhaled breath condensate (EBC) is robust and simple. Acidic source fluid (airway lining fluid) traps bases while volatilising acids, leading to EBC acidification in many lung diseases. Lower airway ammonia is one determinant of airway lining fluid pH, raising the concern that addition of the base ammonia by contamination from the mouth might confound EBC pH assays. METHODS Three discrete methods were used to limit oral ammonia contamination of EBC collections: endotracheal intubation, oral rinsing, and -40 degrees C condenser temperatures. Separately, ammonia was removed from collected EBC samples by lyophilisation and resuspension. Intraweek and intraday variability of ammonia concentration was determined in 76 subjects, and ammonia and pH from a further 235 samples were graphically compared. Ammonia was assayed spectrophotometrically and pH was assessed after deaeration. RESULTS Data from 1091 samples are presented. Ammonia was reduced in EBC by all methods. Endotracheal intubation decreased EBC ammonia from a mean (SD) of 619 (124) microM to 80 (24) microM (p<0.001, n=32). Oral rinsing before collection also led to a decline in EBC ammonia from 573 (307) microM to 224 (80) microM (p=0.016, n=7). The colder the condensation temperature used, the less ammonia was trapped in the EBC. Lyophilisation removed 99.4 (1.9)% of ammonia. Most importantly, the pH of EBC never decreased after removal of ammonia by any of these methods. Intraweek and intraday coefficients of variation for ammonia were 64 (27)% and 60 (32)%, which is substantially more variable than EBC pH assays. CONCLUSIONS Although ammonia and pH appear to correlate in EBC, the oral ammonia concentration is not an important determinant of EBC pH. No precautions need to be taken to exclude oral ammonia when EBC pH is of interest. The low pH and low ammonia found in EBC from patients with lung diseases appear to be independent effects of volatile compounds arising from the airway.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Exhaled breath condensate: methodological recommendations and unresolved questions.

Collection of exhaled breath condensate (EBC) is a noninvasive method for obtaining samples from the lungs. EBC contains large number of mediators including adenosine, ammonia, hydrogen peroxide, isoprostanes, leukotrienes, nitrogen oxides, peptides and cytokines. Concentrations of these mediators are influenced by lung diseases and modulated by therapeutic interventions. Similarly EBC pH also ...

متن کامل

A physiological-social score for triaging of pandemic influenza patients.

In summary, argon deaeration decreases the concentration and the variability of exhaled breath condensate partial pressure of CO2, but there is always some remaining CO2 that may still be a confounding factor in pH assessment. CO2 content has a marked influence on exhaled breath condensate pH and, since exhaled breath condensate partial pressure of CO2 varies even after deaeration, it leaves so...

متن کامل

Independent information of nonspecific biomarkers in exhaled breath condensate.

BACKGROUND Exhaled breath condensate (EBC) has been used for diagnosing and monitoring respiratory disorders. For clinical purposes the assessment of easy-to-obtain nonspecific markers seems particularly interesting. OBJECTIVES As these measures are related to each other, our objective was to extract the independent information in global EBC markers across a range of respiratory disorders. ...

متن کامل

Identification of acid reflux cough using serial assays of exhaled breath condensate pH

BACKGROUND Chronic cough is a common problem, frequently caused or exacerbated by acid reflux. Diagnosis of acid reflux cough is haphazard currently, often relying on long therapeutic trials of expensive medications. We tested the hypothesis that the most relevant mechanistic component of acid reflux in chronic cough is when it rises to the level of the airway where acid can potentially be aspi...

متن کامل

سنجش نشانگر زیستی IL-6در هوای بازدمی با استفاده از دستگاه جمع‌آورنده میعانات بازدمی

Background and Objective: The collection of exhaled breath condensate (EBC) is a noninvasive, safe and simple technique to obtain direct samples from lung and use for estimation of the effects of air pollution on human subjects. EBC contains several compounds including simple ions, hydrogen peroxide, proteins, cytokines, deoxyribonucleic acid (DNA), creatine, Electrolytes, trace elements and to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Thorax

دوره 60 1  شماره 

صفحات  -

تاریخ انتشار 2005