Quality Control of Radiopharmaceutical Dose Calibrators in Nuclear Medicine Unit

نویسنده

  • Lucindo Junior
چکیده

As part of the program to ensure quality in nuclear medicine unit, in addition to diagnostic procedures, are evaluated activity meters, which is intended to measure the aliquot of radiation of radionuclides and / or radiopharmaceuticals that are administered to patients undergoing diagnostic investigation and / or therapeutic treatment. The good operating condition of dose calibrators is essential to ensure efficiency, safety and reliability of the measurements, once the lack of accuracy in the responses of these equipments can cause significant errors in the activity administered to the patient and may result in poor quality images resulting in the repetition of examis and interference in the successful treatment of the patient. This study aims to, considering the need for constant evaluation of the functioning of the activity meters and the fact that this issue be part the responsibilities of the professional of radiology, perform quality control testing of these instruments in relation to the most recent norm of National Commission of nuclear Energy (CNEN-NN 3:05) in Brazil, that is also in according to the international standards and reference values established during acceptance testing of these instruments in a nuclear medicine service. For this, was made a review of specific literature and the use of barium, cobalt and cesium to the tests in a nuclear medicine service of the state of Pernambuco in Brazil. The obtained results of the specific tests utilized to verify the correct working of the dose calibrators show coherency with the resolutions of the CNEN-NN 3:05 and are also in agreement with the international standards to that the measurement of activities be made with accurate results and thereby contribute to the proper functioning of nuclear medicine service.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An investigation on the performance of dose calibrators in nuclear medicine centers in Iran

Background: To investigate the status of the nuclear medicine (NM) centers in Iran for the performance of dose calibrators, 18 out of 54 centers providing NM services in Iran were randomly selected and inspected in 1997. In the first phase of the study the selected centers were inspected for performing of quality control (QC) tests of dose calibrators. The linearity of the activity res...

متن کامل

Synthesis, Quality Control and Stability Studies of 2-[18F]Fluoro-2-Deoxy-D-Glucose(18F-FDG) at Different Conditions of Temperature by Physicochemical and Microbiological Assays

The introduction of 2-[18F] fluor-2-deoxy-D-glucose (18FDG) has provided a valuable tool for the study of glucose metabolism in both normal and diseased tissue in conjunction with positron emission tomography (PET). 18FDG is the most important radiopharmaceutical to be used in Nuclear Medicine for studying the brain, heart and tumor. The advancement in synthesis and quality control of 18FDG and...

متن کامل

Synthesis, Quality Control and Stability Studies of 2-[18F]Fluoro-2-Deoxy-D-Glucose(18F-FDG) at Different Conditions of Temperature by Physicochemical and Microbiological Assays

The introduction of 2-[18F] fluor-2-deoxy-D-glucose (18FDG) has provided a valuable tool for the study of glucose metabolism in both normal and diseased tissue in conjunction with positron emission tomography (PET). 18FDG is the most important radiopharmaceutical to be used in Nuclear Medicine for studying the brain, heart and tumor. The advancement in synthesis and quality control of 18FDG and...

متن کامل

Synthesis, formulation and quality control of 99mTc-MAG3, as a renal tubular 99mTc-radiopharmaceutical kit [Persian]

Radionuclidic techniques may provide assessment of glomerular filtration rate (GFR) effective renal plasma flow (ERPF) or individual renal function. Several agents were available for determination of these parameters such as ¹³¹I-OIH (O-iodohippurate) and different derivatives of DADS (Diamidodisulfur). OIH has the disadvantage of imparting a relatively high absorbed radiation dose to the...

متن کامل

Production and quality control of 166Ho-Chitosan for therapeutic applications

Introduction: In this research, [166Ho]Holmium chitosan complex production is described in details, followed by determination of complex radiochemical purity, stability and biodistribution (after intra-articular injection) in wild-type male rats. Finally a Ho-166 based chitosan kit for ultimate radiosynovectomy as well as radiotherapy applications was developed. Methods: 166</s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015