The accuracy of a system for reconstructing a three dimensional image of the left ventricle from randomly recorded multiple short axis images was tested by comparing the calculated left ventricular volume with the directly measured left ventricular volume in 11 excised porcine hearts. The system comprised a real time phased array sector scanner, a transducer locating system, and a computer system for digitising outlines of the left ventricle, displaying the reconstruction image, and calculating the left ventricular volume. The reconstructed image was similar to the real image and the calculated left ventricular volume showed a high correlation with the directly measured left ventricular volume. This method was accurate in vitro and is expected to be available for clinical measurement of left ventricular volume.
منابع مشابه
Normal Value of Left Ventricular End-Systolic Elastance in Infants and Children
Background: In certain conditions, there is a need for a specific and improved measure of cardiac performance. Routine methods for assessing left ventricular (LV) function are based on image-analysis or right heart monitoring which do not allow evaluation of ventriculo-arterial interaction. Chen et al presented a noninvasive method allowing measurement of end-systolic pressure–volume relation ...
متن کاملRight ventricular Hemodynamic Alteration after Pulmonary Valve Replacement in Children with Congenital Heart Disease
Introduction: In patients who underwent surgery to repair Tetralogy of Fallot, right ventricular dilation from pulmonary regurgitation may be result in right ventricular failure, arrhythmias and cardiac arrest. Hence, pulmonary valve replacement may be necessary to reduce right ventricular volume overload. The aim of present study was to assess the effects of pulmonary valve replacement on rig...
متن کاملThe Correlation between Left and Right Ventricular Ejection Fractions in Patients with Ischemic Heart Disease, Documented by Cardiac Magnetic Resonance Imaging
Introduction: The correlation between right and left ventricular ejection fractions (RVEF and LVEF, respectively) has been studied in only a small number of patients with a marked decrease in RVEF and LVEF. The aim of the present study was to compare LVEF and RVEF in patients with ischemic heart disease. RVEF and LVEF were measured by Cardiovascular Magnetic Resonance (CMR) imaging. Materials a...
متن کاملبررسی اثر کاهش حجم بر روی پارامترهای دیاستولیک اکو کاردیوگرافی در بیماران همودیالیزی
Background: Cardiovascular problems including arterial hypertension, coronary artery diseases, congestive heart failure are prevalent among chronic hemodialyzed patients. Ultrafiltration of hemodialyzed patient's serum, which culminating in intravascular volume reduction, is frequently used during hemodialysis. One of the restrictions of the echocardiographic evaluation of the diastolic heart f...
متن کاملMeasure the gap! A proposed simplified approach for measuring the descent of the base of the left ventricle.
The evaluation of left ventricular systolic function represents a common request for an echocardiographic examination. Several parameters have been proposed to quantitate left ventricular systolic function. The descent of the base of the left ventricle is founded on sound principle but currently requires multiple, time-consuming steps to derive during an echocardiographic examination. This arti...