EMI in Modern AC Motor Drive Systems

نویسنده

  • Firuz Zare
چکیده

In this paper, several aspects of high frequency related issues of modern AC motor drive systems, such as common mode voltage, shaft voltage and resultant bearing current and leakage currents, have been discussed. Conducted emission is a major problem in modern motor drives that produce undesirable effects on electronic devices. In modern power electronic systems, increasing power density and decreasing cost and size of system are market requirements. Switching losses, harmonics and EMI are the key factors which should be considered at the beginning stage of a design to optimise a drive system. Introduction Nowadays, more than 60 percent of the world’s energy is used to drive electric motors. Due to growing requirements of speed control, pulse width modulated inverters are used in adjustable speed drives. Rapid developments in semiconductor technology have increased the switching speed and frequency of power switches dramatically. In a motor drive system, a voltage source converter with hard switches generates high dv/dt, which causes leakage currents due to stray capacitances in an electric motor. As shown in Fig.1, a modern power electronic drive consists of a filter, a rectifier, a DC link capacitor, an inverter and an AC motor. Many small capacitive couplings exist in the motor drive systems which may be neglected at low frequency analysis but the conditions are completely different at high frequencies. Electromagnetic Interference (EMI) is a major problem in recent motor drives that produces undesirable effects on electronic devices. In modern power electronic systems, increasing power density and decreasing cost and size of a system are market requirements. Switching losses, harmonics and EMI are the key factors which should be considered at the beginning stage of a design to optimise a drive system. Common mode voltage creates shaft voltage through electrostatic couplings between a rotor and stator windings and the rotor and a frame which can cause bearing currents when the shaft voltage exceeds a breakdown voltage level of the bearing grease. An increase in the carrier frequency of voltage-source Pulse Width Modulated (PWM) inverters based on high-speed switching devices has improved operating characteristics of the inverters. High speed switching can generate the following serious problems due to high dv/dt: Ground current escaping to earth through stray capacitors • inside a motor Conducted and radiated noises • Shaft voltage and bearing current • Models of parasitic couplings and high frequency components for an inverter fed induction motor drive system are investigated to determine suitable models to predict

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Novel Active Filter for Mitigation of EMI and Other Adverse Effects of PWM Inverter-Fed AC Motor

This paper presents novel active filter for mitigation electromagnetic interference (EMI) and other adverse effects of pulse width modulation (PWM) inverter-fed AC motor system. An active filter proposed and devised for this system is characterized by sophisticated connection of two small separate filters, capable of mitigating all the adverse effects. This paper provides high frequency models ...

متن کامل

The Effect of Distributed Parameters on Conducted EMI from DC-Fed Motor Drive Systems in Electric Vehicles

The large dv/dt and di/dt outputs of power devices in DC-fed motor drive systems in electric vehicles (EVs) always introduce conducted electromagnetic interference (EMI) emissions and may lead to motor drive system energy transmission losses. The effect of distributed parameters on conducted EMI from the DC-fed high voltage motor drive systems in EVs is studied. A complete test for conducted EM...

متن کامل

Analysis of EMI conducted by a PWM inverter - fed AC motor drive

This work analyses the conducted EMI generated by an inverter-fed induction motor drive system with the pulse with modulation (PWM) as one of the most difficult current technical problem which limits power electronics drive's evolution. The analysis of the impedance characteristics of the converters load (motor and cable) is fundamental to interpret the common and differential mode of emission ...

متن کامل

New method of Electromagnetic Interferences Reduction in AC-AC power converter fed Induction motor drive

The aim of this paper is to study the effect of EMI in Switched mode PWM Inverter fed AC drive. This Switched mode PWM Inverter has an inherent noise source. This noise is mitigated by a New Active Common Mode Electro Magnetic Interference Filter (ACEF) which is proposed for switched mode power supply applications. The proposed filter is based on current sensing and a compensation circuit which...

متن کامل

Modified Bi-directional AC/DC Power Converter with Power Factor Correction

Most existing power  converters and industrial motor drive systems draw non-sinusoidal currents from the supply. Non-sinusoidal currents contained harm harmonics disturb the power supply which it causes serious concern for reliability. Other equipments that use the same power supply are adversely affected. This paper suggests the operation and performance of a new modified AC/DC converter that ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009