Are melodic medical equipment alarms easily learned?

نویسندگان

  • Alexandra N Wee
  • Penelope M Sanderson
چکیده

BACKGROUND We tested melodic auditory alarms recommended in the IEC 60601-1-8 standard for medical electrical equipment for ease of learning and discrimination, and for effectiveness during a timeshared task. METHODS Twenty-two critical care nurses learned the IEC 60601-1-8 melodic alarms over two training sessions more than a week apart, with or without mnemonics suggested in the standard. Subsequently, the nurses identified alarms arriving at quasi random intervals while performing a timeshared arithmetic task. RESULTS Only one nurse (4.5%) identified the alarms with 100% accuracy after two training sessions. Mnemonics did not improve overall alarm identification accuracy (mnemonic = 56%, nonmnemonic = 55%) but led to a narrower range of confusions between alarms. Nurses responded faster (P < 0.0001) and more accurately (P = 0.032) to medium priority than high priority alarms, despite rating high priority alarms as sounding more urgent (P < 0.0001). Nurses with at least 1 yr of formal musical training identified the alarms much more accurately (musical training = 73%, no musical training = 38%, P < 0.0001), perceived a greater distinction between high and medium priority alarms (P = 0.002), and found identifying the alarms easier overall (P = 0.023). During the timeshared task, nurses' responses were slower (P = 0.002) and became less accurate (P = 0.02). CONCLUSIONS The slow rate of learning and persistent confusions suggest that the IEC 60601-1-8 melodic alarms should be redesigned before they are adopted for clinical practice.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Overlapping Melodic Alarms Are Almost Indiscriminable

OBJECTIVE We explore how accurately and quickly nurses can identify melodic medical equipment alarms when no mnemonics are used, when alarms may overlap, and when concurrent tasks are performed. BACKGROUND The international standard IEC 60601-1-8 (International Electrotechnical Commission, 2005) has proposed simple melodies to distinguish seven alarm sources. Previous studies with nonmedical ...

متن کامل

Learnability and discriminability of melodic medical equipment alarms.

Melodic alarms proposed in the IEC 60601-1-8 standard for medical electrical equipment were tested for learnability and discriminability. Thirty-three non-anaesthetist participants learned the alarms over two sessions of practice, with or without mnemonics suggested in the standard. Fewer than 30% of participants could identify the alarms with 100% accuracy at the end of practice. Confusions pe...

متن کامل

Do mnemonics help nurses learn melodic medical equipment alarms?

We tested the melodic alarms and mnemonics proposed in the international standard for alarms used in medical electrical equipment (IEC 60601-1-8) for learnability and discriminability, with 14 registered nurses over two days, approximately a week apart. Two learning modes (Mnemonics and No Mnemonics) were examined in computer administered tests. The first experimental group was supplied with mn...

متن کامل

"For if the trumpet give an uncertain sound, who shall prepare himself to the battle?" (I Corinthians 14:8, KJV).

Frank E. Block, Jr., MD Every clinician is well aware of the problems with audible alarms: False alarms, loud alarms, difficulty determining what is alarming, and inability to quiet an alarm all create distractions that impede patient care. These problems are complicated by the different approaches to alarms among devices. Devices designed by various manufacturers may use different alarm sounds...

متن کامل

Testing New Alarms for Medical Electrical Equipment

This paper reports the first of several tests of new auditory alarms originally proposed by Block et al. [1] and formalized in IEC 60601-1-8 for use in medical electrical equipment. We test whether participants who are supplied with the IEC-recommended mnemonics while learning label-alarm associations can more accurately identify the alarms after short periods of learning. Results for 18 partic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesia and analgesia

دوره 106 2  شماره 

صفحات  -

تاریخ انتشار 2008