Determination of Metoprolol and Felodipine in Binary Mixture Using Chemometric- Assisted Spectrophotometric and High-Performance Liquid Chromatographic-UV Mmethods
نویسندگان
چکیده
Four methods were developed for simultaneous determination of metoprolol and felodipine without previous separation. In the first method both drugs were determined using first derivative UV spectrophotometry, with zero crossing measurement at 222 and 235 nm for metoprolol and felodipine, respectively. The second method depends on first derivative of the ratios spectra by measurements of the amplitudes at 250.1 nm for metoprolol and 224.3 nm for felodipine. Calibration graphs are established in the range of 20-150 μg/ml and 10-60 μg/ml for metoprolol and felodipine, respectively. The third method describes the use of multivariate spectrophotometric calibration for the simultaneous determination of the analyzed binary mixture where the resolution is accomplished by using partial least squares (PLS) regression analysis. Although the components show high degree of spectral overlap, they are simultaneously determined with high accuracy and without interference of pharmaceutical dosage form excipients. A comparison with the related multivariate method of classicial least squares (CLS) analysis is done showing less relative results due to severe spectral overlap of the studied drugs. In the fourth method (HPLC), a reversed-phase column and a mobile phase of methanol:water:acetonitrile (70:22:8 v/v/v/) at 0.9 ml/min flow rate is used to separate both drugs and UV detection at 260 nm. Good linearities are obtained in concentration range of 0.15-15 μg/ml for metoprolol and 0.03-5 μg/ml for felodipine. All the proposed methods are extensively validated. They have the advantage of being economic and time saving. All the described methods can be readily utilized for the analysis of pharmaceutical formulations, the fourth method (HPLC) is successfully applied for the analysis of both drugs in human serum samples. The results obtained by adopting the proposed methods are statistically analyzed and compared with those obtained by reported methods.
منابع مشابه
Simple, Fast and Reliable Liquid Chromatographic and Spectrophotometric Methods for the Determination of Theophylline in Urine, Saliva and Plasma Samples
In this study, a high-performance liquid chromatographic method (HPLC) and UV spectrophotometric method were developed, validated and applied for the determination of theophylline in biological fluids. Liquid- liquid extraction is performed for isolation of the drug and elimination of plasma and saliva interferences. Urine samples were applied without any extraction. The chromatographic separat...
متن کاملSimple, Fast and Reliable Liquid Chromatographic and Spectrophotometric Methods for the Determination of Theophylline in Urine, Saliva and Plasma Samples
In this study, a high-performance liquid chromatographic method (HPLC) and UV spectrophotometric method were developed, validated and applied for the determination of theophylline in biological fluids. Liquid- liquid extraction is performed for isolation of the drug and elimination of plasma and saliva interferences. Urine samples were applied without any extraction. The chromatographic separat...
متن کاملDetermination of Amlodipine and Valsartan in Binary Mixture Using Derivative- Ratio Spectrophotometric, Chemometric and High Performance Liquid Chromatographic-UV Methods
Three methods were developed for simultaneous determination of amlodipine and valsartan without previous separation. The first method depends on first derivative of the ratios spectra (DD1) by measurements of the amplitudes at 234.5 and 247 nm for amlodipine using 30μg/mL of valsartan as a divisor and at 282 and 292 nm for valsartan using 80μg/mL of amlodipine as a divisor. Calibration graphs w...
متن کاملRapid High Performance Liquid Chromatographic Determination of Risperidone in Human Plasma
A simple, rapid and sensitive high-performance liquid chromatographic (HPLC) method for the determination of risperidone in human plasma was developed. An HPLC system based on a Nucleosil C8 column (150?4 mm) and a UV detector (?= 280 nm) were used. A mixture of sodium dihydrogen phosphate buffer-acetonitrile (55:45, v/v) adjusted to pH 6.0 at a flow rate of 1.5 ml min-1 was used as mobile phas...
متن کاملRapid High Performance Liquid Chromatographic Determination of Risperidone in Human Plasma
A simple, rapid and sensitive high-performance liquid chromatographic (HPLC) method for the determination of risperidone in human plasma was developed. An HPLC system based on a Nucleosil C8 column (150?4 mm) and a UV detector (?= 280 nm) were used. A mixture of sodium dihydrogen phosphate buffer-acetonitrile (55:45, v/v) adjusted to pH 6.0 at a flow rate of 1.5 ml min-1 was used as mobile phas...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -