Early experiences with robot-assisted total knee arthroplasty using the DigiMatch™ ROBODOC® surgical system.
نویسندگان
چکیده
INTRODUCTION The use of robotics in total knee arthroplasty (TKA) has been shown to minimise human error, as well as improve the accuracy and precision of component implantation and mechanical axis alignment. The present study aimed to demonstrate that robot-assisted TKA using ROBODOC® is safe and capable of producing a consistent and accurate postoperative mechanical axis. METHODS We prospectively recruited 27 consecutive patients who underwent robot-assisted TKA between May and December 2012. Two patients were excluded from the study due to intraoperative technical problems with the robot. Long-leg radiography and computed tomography were performed prior to surgery, and used for mechanical axis measurements and component sizing. DigiMatch™ ROBODOC® Surgical System software version 4.3.6 (Curexo Technology Corp, Fremont, CA, USA) was used in all cases to perform bone cuts in accordance with the preoperative plan. RESULTS The postoperative coronal mechanical alignment was within 3 degrees, with a mean alignment of -0.4 ± 1.7 degrees, confirming the accuracy of the preoperative surgical plan and bone cuts. The mean operating time was 96 ± 15 min, and preoperative planning yielded 100% implant sizing accuracy. CONCLUSION Robotics has the potential to enable surgeons to consistently attain ideal postoperative alignment. The use of bone movement monitors and an integrated navigation system enhances the safety profile of ROBODOC® by minimising errors. However, the role of the surgeon in TKA is still vital, as the surgeon is ultimately in charge of planning the surgery, its execution and ensuring soft tissue balance during TKA.
منابع مشابه
THINK surgical TSolution-One® (Robodoc) total knee arthroplasty
THINK Surgical TSolution-One® is an active-autonomous, image-based, robotic milling system which enables the surgeon to attain a consistently accurate implant component positioning. The TSolution-One® system is capable of achieving this through an image-based preoperative planning system which allows the surgeon to create, view and analyse the surgical outcome in 3D. The accuracy and precision ...
متن کاملComparison of robot-assisted and conventional total knee arthroplasty: a controlled cadaver study using multiparameter quantitative three-dimensional CT assessment of alignment.
INTRODUCTION A functional total knee replacement has to be well aligned, which implies that it should lie along the mechanical axis and in the correct axial and rotational planes. Incorrect alignment will lead to abnormal wear, early mechanical loosening, and patellofemoral problems. There has been increased interest of late in total knee arthroplasty with robotic assistance. This study was con...
متن کاملRobotic systems in orthopaedic surgery.
Robots have been used in surgery since the late 1980s. Orthopaedic surgery began to incorporate robotic technology in 1992, with the introduction of ROBODOC, for the planning and performance of total hip replacement. The use of robotic systems has subsequently increased, with promising short-term radiological outcomes when compared with traditional orthopaedic procedures. Robotic systems can be...
متن کاملState of the art in computer-assisted orthopaedic THR and TKR
Computer assisted orthopaedic surgery (CAOS) was developed to improve the accuracy of surgical procedures, and it has dramatically improved in the last years from an experimental laboratory procedure to a routine procedure theoretically available for every orthopaedic surgeon. Besides robotic application, surgical navigation has been widely developed for joint arthroplasties, mostly for total k...
متن کاملComputer-assisted surgical navigation does not improve the alignment and orientation of the components in total knee arthroplasty.
BACKGROUND Whether total knee arthroplasty with use of computer-assisted surgical navigation can improve the limb and component alignment is a matter of debate. We hypothesized that total knee arthroplasty with use of computer-assisted surgical navigation is superior to conventional total knee arthroplasty with regard to the precision of implant positioning. METHODS Sequential simultaneous bi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Singapore medical journal
دوره 55 10 شماره
صفحات -
تاریخ انتشار 2014