On the resolution and linearity of lensless in situ X-ray beam diagnostics using pixelated sensors.

نویسندگان

  • Anton Kachatkou
  • Roelof van Silfhout
چکیده

We present a theoretical model that describes the resolution and linearity of a novel transparent X-ray beam imaging and position measurement method. Using a pinhole or coded aperture camera with pixelated area sensors to image a small fraction of radiation scattered by a thin foil placed at oblique angles with respect to the beam, a very precise measurement of the beam position is made. We show that the resolution of the method is determined by incident beam intensity, beam size, camera parameters, sensor pixel size and noise. The model is verified experimentally showing a sub-micrometer resolution over a large linear range.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In situ micro-focused X-ray beam characterization with a lensless camera using a hybrid pixel detector

Results of studies on micro-focused X-ray beam diagnostics using an X-ray beam imaging (XBI) instrument based on the idea of recording radiation scattered from a thin foil of a low-Z material with a lensless camera are reported. The XBI instrument captures magnified images of the scattering region within the foil as illuminated by the incident beam. These images contain information about beam s...

متن کامل

New approach for calibration of pixelated scintillation detectors of intraoperative gamma cameras

Introduction:SURGEOSIGHT is a dedicated intra-operative hand-held gamma camera designed and manufactured by our team to be used for lymphoscintigraphy. Although conventional gamma cameras are widely used, they lack the capability of the sentinel lymph node (SLN) imaging in the operation room. Like conventional gamma cameras it is necessary to calibrate SURGEOSIGHT for linearity...

متن کامل

Optimization of an ultra-high-resolution rectangular pixelated parallel-hole collimator with a CZT pixelated semiconductor detector for HiRe-SPECT system

Introduction: In nuclear medicine, the use of a pixelated semiconductor detector such as CZT is an of growing interest for introducing new devices. Especially, the spatial resolution can be improved by using a pixelated parallel-hole collimator with equal holes and pixel sizes based on the pixelated detector. The purpose of this study was to compare the effect of pixelated and ...

متن کامل

Lensless diffractive imaging using tabletop coherent high-harmonic soft-X-ray beams.

We present the first experimental demonstration of lensless diffractive imaging using coherent soft x rays generated by a tabletop soft-x-ray source. A 29 nm high harmonic beam illuminates an object, and the subsequent diffraction is collected on an x-ray CCD camera. High dynamic range diffraction patterns are obtained by taking multiple exposures while blocking small-angle diffraction using be...

متن کامل

Real-time in-situ X-ray beam diagnostics

We report on a novel diagnostics instrument for in-situ imaging and measurements of X-ray beam parameters in real-time. The instrument is based on the robust and simple idea of a pinhole camera that collects the weakly scattered radiation from a thin sheet of a low-Z material placed in the X-ray beam at an acute angle. We demonstrate how by recording the scattered radiation with an appropriate ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optics express

دوره 21 4  شماره 

صفحات  -

تاریخ انتشار 2013