Determining Consensus Values in Interlaboratory Comparisons and Proficiency Testing

نویسنده

  • Henrik S. Nielsen
چکیده

An important part of interlaboratory comparisons and proficiency testing is the determination of the reference value of the measurand and the associated uncertainty. It is desirable to have reference values with low uncertainty, but it is crucial that these values are reliable, i.e. they are correct within their stated uncertainty. In some cases it is possible to obtain reference values from laboratories that reliably can produce values with significantly lower uncertainty than the proficiency testing participants, but in many cases this is not possible for economical or practical reasons. In these cases a consensus value can be used as the best estimate of the measurand. A consensus value has the advantage that it often has a lower uncertainty than the value reported by the reference laboratory. There are well known and statistically sound methods available for combining results with different uncertainties, but these methods assume that the stated uncertainty of the results is correct, which is not a given. In fact, the very purpose of proficiency testing is to establish whether the participants can measure within their claimed uncertainty. The paper explores a number of methods for determining preliminary consensus values used to determine which participant values should be deemed reliable and therefore included in the calculation of the final consensus value and its uncertainty. Some values are based on impressive equations and others have curious names. The relative merits of these methods in various scenarios are discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of computer modeling to predict the magnitude of intralaboratory error tolerated by proposed CDC interlaboratory proficiency testing performance criteria.

In December 1987, the Centers for Disease Control (CDC) proposed to the Health Care Financing Administration revised criteria for evaluating participating laboratories' performance in proficiency-testing programs. If these criteria are accepted, they will become the minimum standard for all regulatory proficiency-testing programs. To evaluate a laboratory's performance in a clinical chemistry p...

متن کامل

Statistics in Metrology: International Key Comparisons and Interlaboratory Studies

Stochastic modeling and analysis of international key comparisons (interlaboratory comparisons) pose several fundamental questions for statistical methodology. A key comparison (KC) is specifically designed to derive the key comparison reference value and to assess conformance of calibrations by participating national metrology laboratories at a few, “key”, settings for a particular measurement...

متن کامل

International interlaboratory proficiency testing program for measurement of azole antifungal plasma concentrations.

An international interlaboratory proficiency testing program for the measurement of antifungal drugs was initiated in 2007. This first round was limited to azole antifungals: fluconazole, itraconazole and hydroxyitraconazole, voriconazole, and posaconazole. The results demonstrate the need for and utility of an ongoing proficiency testing program to further improve the analytical methods for ro...

متن کامل

Proficiency test performance as a predictor of accuracy of routine patient testing for theophylline.

Proficiency testing (PT) is pivotal in assessing laboratory qualifications for certification and licensure. PT is expected to typify routine assay performance and determine whether the laboratory is producing clinically useful test results. Conventional schemes use mail-distributed test specimens and are often criticized as measuring the best possible laboratory performance, principally because...

متن کامل

National Association for Proficiency Testing

These suggestions are as follows: 1) Regular use of certified reference materials and/or internal quality control using secondary reference materials 2) Participation in interlaboratory comparison or proficiency testing programs 3) Replicate tests or calibrations using the same or different methods 4) Retesting or recalibration of retained items 5) Correlation of results for different character...