Online Investigation of Aqueous-Phase Electrochemical Reactions by Desorption Electrospray Ionization Mass Spectrometry.
نویسندگان
چکیده
Electrochemistry (EC) combined with mass spectrometry (MS) is a powerful tool for elucidation of electrochemical reaction mechanisms. However, direct online analysis of electrochemical reaction in aqueous phase was rarely explored. This paper presents the online investigation of several electrochemical reactions with biological relevance in the aqueous phase, such as nitrosothiol reduction, carbohydrate oxidation, and carbamazepine oxidation using desorption electrospray ionization mass spectrometry (DESI-MS). It was found that electroreduction of nitrosothiols [e.g., nitrosylated insulin B (13-23)] leads to free thiols by loss of NO, as confirmed by online MS analysis for the first time. The characteristic mass shift of 29 Da and the reduced intensity provide a quick way to identify nitrosylated species. Equally importantly, upon collision-induced dissociation (CID), the reduced peptide ion produces more fragment ions than its nitrosylated precursor ion (presumably the backbone fragmentation cannot compete with the facile NO loss for the precursor ion), thus facilitating peptide sequencing. In the case of saccharide oxidation, it was found that glucose undergoes electro-oxidation to produce gluconic acid at alkaline pH, but not at neutral and acidic pHs. Such a pH-dependent electrochemical behavior was also observed for disaccharides such as maltose and cellobiose. Upon electrochemical oxidation, carbamazepine was found to undergo ring contraction and amide bond cleavage, which parallels the oxidative metabolism observed for this drug in leucocytes. The mechanistic information of these redox reactions revealed by EC/DESI-MS would be of value in nitroso-proteome research and carbohydrate/drug metabolic studies.
منابع مشابه
Electrochemical reactions and ionization processes.
Electrochemical or photo-electrochemical reactions in both electrospray ionization and laser desorption ionization are discussed stressing the role of the electrode reaction in influencing the ionization process. In particular, upon application of a high voltage during electrospray ionization, the emitter includes a working electrode, where redox reactions are observed, such as electro-generati...
متن کاملDroplet Analysis with Electrospray Ionization Mass Spec- Trometry Using an Integrated Glass Microchip
ABSTRACT We describe an integrated microchip for droplet analysis with electrospray ionization mass spectrometry (ESI-MS). The chip integrated multiple modules of droplet generator, droplet extraction interface, and monolithic ESI-emitter. A novel droplet extraction interface based on a hydrophilic tongue structure was developed to transfer droplet from segmented phase to aqueous phase with hig...
متن کاملElectrospray ionization mass spectrometry: a major tool to investigate reaction mechanisms in both solution and the gas phase.
Electrospray ionization mass spectrometry (ESI-MS), in conjunction with its tandem version ESI-MS/MS, is now established as a major tool to study reaction mechanisms in solution. This suitability results mainly from the ability of ESI to "fish" ions directly from solution to the gas phase environment of mass spectrometers. In this review, we summarize recent studies from our laboratory on the u...
متن کاملOnline monitoring of chemical reactions by contactless atmospheric pressure ionization mass spectrometry.
Online monitoring of the appearance of the intermediates and products during chemical reactions is helpful to understand reaction mechanisms. Various analytical tools including nuclear magnetic resonance spectroscopy, Raman spectroscopy and mass spectrometry (MS) have been employed for the study. MS is one of the most promising means among analytical tools that can provide information of mass-t...
متن کاملDirect analysis of liquid samples by desorption electrospray ionization-mass spectrometry (DESI-MS).
Desorption electrospray ionization-mass spectrometry (DESI-MS) was evaluated for the direct analysis of liquid samples. Several interesting results were found. First, in contrast to the previous DESI analysis of dried solid samples that was limited to proteins with MW < or = 25 kDa (Anal. Chem. 2007, 79, 3514), bovine serum albumin (BSA, 66 kDa) was successfully ionized from solutions by DESI w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of the American Society for Mass Spectrometry
دوره 26 10 شماره
صفحات -
تاریخ انتشار 2015