Wavefront ablation profiles in refractive surgery: description, results, and limitations.

نویسندگان

  • David Smadja
  • Glauco Reggiani-Mello
  • Marcony R Santhiago
  • Ronald R Krueger
چکیده

PURPOSE To provide an overview of the clinical results of different ablation profiles based on wavefront technology and discuss their characteristics and limitations. METHODS Literature review of studies reporting results of ablation profiles based on wavefront technology in virgin healthy eyes. RESULTS Over the past 10 years, a large number of studies comparing different treatment algorithms and newer excimer laser platforms have been published. Thirty-six clinical studies including 3637 eyes analyzing the clinical results obtained after wavefront-guided, wavefront-optimized, and Q-factor profiles have been reviewed. Although wavefront-driven profiles allowed reduction of the amount of induced optical aberrations with conventional ablations, thereby improving the quality of vision, it appears that no algorithm of treatment or excimer laser platform has demonstrated a clear superiority over another. Wound healing and unexpected biomechanical response to surgery affect the accuracy of customized treatments and produce variable results. In addition, it is difficult to rigorously analyze and compare findings among different studies because of the diverse variety in which the data are reported. CONCLUSIONS Despite several technological improvements over the years, wavefront ablation profiles have not consistently demonstrated superiority in terms of visual acuity and lower order aberrations compared to the standard procedure, although the induction of higher order aberrations has been reduced. The concept of an individualized eye model has emerged recently, based on the optical ray tracing algorithm, and could theoretically provide a higher level of customization, thus fulfilling the promise of "super vision."

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Q-factor customized ablation profile for the correction of myopic astigmatism.

PURPOSE To compare the results of the Q-factor customized aspheric ablation profile with the wavefront-guided customized ablation pattern for the correction of myopic astigmatism. SETTING Institute for Refractive and Ophthalmic Surgery, Zurich, Switzerland. METHODS Thirty-five patients were enrolled in a controlled study in which the nondominant eye was treated with the Q-factor customized ...

متن کامل

Wavefront aberrometry in Cataract Surgery and Laser vision Correction

66 CataraCt & refraCtive Surgery today euroPe SePtember 2012 The Munnerlyn ablation profiles first used in laser vision correction did not respect the normal prolate shape of the cornea. As a result, these profiles induced aberrations that reduced patients’ quality of vision. In recent years, enhanced understanding and technological adaptation to address spherocylindrical refractive error and h...

متن کامل

Clinical outcomes of LASIK for myopia using the SCHWIND platform with ocular wavefront customized ablation.

PURPOSE To evaluate the clinical outcomes of aspheric ocular wavefront ablation profiles in LASIK treatments. METHODS Thirty eyes treated by ocular wavefront were retrospectively analyzed at 6-month follow-up. Custom Ablation Manager (CAM) software was used to plan wavefront-customized aspheric treatments, and the ESIRIS system was used to perform ablations (SCHWIND eye-tech-solutions). Outco...

متن کامل

Wavefront-guided laser in situ keratomileusis: early results in three eyes.

PURPOSE Wavefront optical aberrations induced by refractive corneal surgery correction of myopia are probably the reason for deterioration of visual performance in some eyes after surgery. Customized photoablation of the cornea to correct both the sphero-cylindrical refractive error as well as individual optical aberrations may improve postoperative visual acuity and visual performance. METHO...

متن کامل

Wavefront- versus topography-guided customized ablations with the NIDEK EC-5000 CX II in surface ablation treatment: refractive and aberrometric outcomes.

PURPOSE To compare the long-term refractive outcomes and changes in higher order wavefront aberrations in patients undergoing photorefractive keratectomy (PRK) with topography-guided (CATz) or wavefront-guided (OPDCAT) ablation algorithm using the NIDEK Advanced Vision Excimer Laser System (NAVEX). METHODS A retrospective 12-month follow-up study was conducted of 226 eyes undergoing PRK. The ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of refractive surgery

دوره 28 3  شماره 

صفحات  -

تاریخ انتشار 2012