Evaluation of sample hemolysis in blood collected by S-Monovette® using vacuum or aspiration mode

نویسندگان

  • Giuseppe Lippi
  • Paola Avanzini
  • Roberta Musa
  • Franca Sandei
  • Rosalia Aloe
  • Gianfranco Cervellin
چکیده

BACKGROUND In vitro hemolysis can be induced by several biological and technical sources, and may be worsened by forced aspiration of blood in vacuum tubes. This study was aimed to compare the probability of hemolysis by drawing blood with a commercial evacuated blood collection tube, and S-Monovette used either in the "vacuum" or "aspiration" mode. MATERIALS AND METHODS The study population consisted in 20 healthy volunteers. A sample was drawn into 4.0 mL BD Vacutainer serum tube from a vein of one upper arm. Two other samples were drawn with a second venipuncture from a vein of the opposite arm, into 4.0 mL S-Monovette serum tubes, by both vacuum an aspiration modes. After separation, serum potassium, lactate dehydrogenase (LD) and hemolysis index (HI) were tested on Beckman Coulter DxC. RESULTS In no case the HI exceed the limit of significant hemolysis. As compared with BD Vacutainer, no significant differences were observed for potassium and LD using S-Monovette with vacuum method. Significant increased values of both parameters were however found in serum collected into BD Vacutainer and S-Monovette by vacuum mode, compared to serum drawn by S-Monovette in aspiration mode. The mean potassium bias was 2.2% versus BD Vacutainer and 2.4% versus S-Monovette in vacuum mode, that of LD was 2.7% versus BD Vacutainer and 2.1% versus S-Monovette in vacuum mode. None of these variations exceeded the allowable total error. CONCLUSIONS Although no significant macro-hemolysis was observed with any collection system, the less chance of producing micro-hemolysis by S-Monovette in aspiration mode suggest that this device may be used when a difficult venipuncture combined with the vacuum may increase the probability of spurious hemolysis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The use of S-Monovette is effective to reduce the burden of hemolysis in a large urban emergency department

BACKGROUND Due to the high prevalence of hemolysis in specimens received from the emergency department (ED), several strategies have been proposed to improve sample quality, but none of these seem effective to overcome the problem. In a preliminary study we showed that the use of S-Monovette blood collection system was effective to lower the risk of hemolysis in venous blood samples collected f...

متن کامل

Critical review and meta-analysis of spurious hemolysis in blood samples collected from intravenous catheters

BACKGROUND A number of preanalytical activities strongly influence sample quality, especially those related to sample collection. Since blood drawing through intravenous catheters is reported as a potential source of erythrocyte injury, we performed a critical review and meta-analysis about the risk of catheter-related hemolysis. MATERIALS AND METHODS We performed a systematic search on PubMe...

متن کامل

Identification and risk assessment in the process of blood donation in a fixed blood collection center of Saqez city by Failure Mode and Effects Analysis

Abstract Background and Objectives Risk is a combination of the likelihood of an incident occurring and the severity of the consequences if that incident were to occur. The aim of this research is to identify and evaluate the risk factors in the blood donation process in a fixed blood collection center of Saqez city by failure mode and effects analysis (FMEA). Materials and Methods It is a des...

متن کامل

Intravascular hemolysis associated with Candidatus Mycoplasma hematoparvum in a non-splenectomized dog in the south region of Iran

A 2-year-old male Pekingese dog was referred to Shiraz University’s Veterinary Teaching Hospital for anorexia and depression. The case had no history of surgery. Physical examination revealed no abnormalities except mild depression and fever. Small, coccoid, epicellular bacteria were detected on erythrocytes by microscopic examination of the Giemsa-stained blood smears. Abnormalities noted in t...

متن کامل

Clotting time analysis of citrated blood samples is strongly affected by the tube used for blood sampling.

Our aim was to establish whether differences in clotting times for recalcified blood and plasma samples might be explained by the use of different blood collection tubes. Samples obtained from different plastic vacuum tubes were recalcified and clotting times determined by free oscillation rheometry. The clotting times for blood collected in Vacutainer (Becton Dickinson, Rutherford, New Jersey,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 23  شماره 

صفحات  -

تاریخ انتشار 2013