Interference of a four-hole aperture for on-chip quantitative two-dimensional differential phase imaging.
نویسندگان
چکیده
We present a novel on-chip method for quantitative two-dimensional differential phase imaging. This technique uses four circular holes (600 nm diameter, 1.2 mum spacing) arranged in a 'plus' pattern that are fabricated in a layer of metal above a complementary metal-oxide semiconductor (CMOS) imaging sensor. The interference pattern of the aperture shifts position with respect to the differential phase of the incident light. By imaging the interference pattern with the CMOS sensor, this method measures amplitude and differential phase (1 degrees /microm sensitivity for signal-to-noise ratio >/=16 dB) of the incident light field simultaneously. An application to optical beam profiling is presented; we show the amplitude and differential phase profiles of a Gaussian laser beam and an optical vortex.
منابع مشابه
On-chip differential interference contrast microscopy using lensless digital holography
We introduce the use of a birefringent crystal with lensless digital holography to create an on-chip differential interference contrast (DIC) microscope. Using an incoherent source with a large aperture, in-line holograms of micro-objects are created, which interact with a uniaxial crystal and an absorbing polarizer, encoding differential interference contrast information of the objects on the ...
متن کاملThree-dimensional differential interference contrast microscopy using synthetic aperture imaging.
We implement differential interference contrast (DIC) microscopy using high-speed synthetic aperture imaging that expands the passband of coherent imaging by a factor of 2.2. For an aperture synthesized coherent image, we apply for the numerical post-processing and obtain a high-contrast DIC image for arbitrary shearing direction and bias retardation. In addition, we obtain images at different ...
متن کاملPhase control and measurement in digital microscopy
The ongoing merger of the digital and optical components of the modern microscope is creating opportunities for new measurement techniques, along with new challenges for optical modelling. This thesis investigates several such opportunities and challenges which are particularly relevant to biomedical imaging. Fourier optics is used throughout the thesis as the underlying conceptual model, with ...
متن کاملDifferential diagnosis of pancreatic cystic masses with the quantitative analysis of spectral CT imaging: Initial results
Background: To retrospectively evaluate whether quantitative information derived from spectral imaging can improve the differential diagnosis of pancreatic cystic masses including pancreatic solid pseudopapillary epithelial neoplasms (SPENs), mucin- producing cysts and pseudocysts. Materials and Methods: From June 2015 to October 2017, 56 patients (22 pseudocysts, 18 mucin-producing cysts and 1...
متن کاملRelationship between fracture dip angle, aperture and fluid flow in the fractured rock masses
Most of the Earth's crust contains fluids, and fractures are common throughout the upper part. They exist at a wide range of scales from micro-fractures within grains to major faults and shear zones that traverse the crust. In this paper, the stress-dependent permeability in fractured rock masses have been investigated considering the effects of nonlinear normal deformation and shear dilation o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Optics letters
دوره 32 20 شماره
صفحات -
تاریخ انتشار 2007