Interference of a four-hole aperture for on-chip quantitative two-dimensional differential phase imaging.

نویسندگان

  • Matthew Lew
  • Xiquan Cui
  • Xin Heng
  • Changhuei Yang
چکیده

We present a novel on-chip method for quantitative two-dimensional differential phase imaging. This technique uses four circular holes (600 nm diameter, 1.2 mum spacing) arranged in a 'plus' pattern that are fabricated in a layer of metal above a complementary metal-oxide semiconductor (CMOS) imaging sensor. The interference pattern of the aperture shifts position with respect to the differential phase of the incident light. By imaging the interference pattern with the CMOS sensor, this method measures amplitude and differential phase (1 degrees /microm sensitivity for signal-to-noise ratio >/=16 dB) of the incident light field simultaneously. An application to optical beam profiling is presented; we show the amplitude and differential phase profiles of a Gaussian laser beam and an optical vortex.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

On-chip differential interference contrast microscopy using lensless digital holography

We introduce the use of a birefringent crystal with lensless digital holography to create an on-chip differential interference contrast (DIC) microscope. Using an incoherent source with a large aperture, in-line holograms of micro-objects are created, which interact with a uniaxial crystal and an absorbing polarizer, encoding differential interference contrast information of the objects on the ...

متن کامل

Three-dimensional differential interference contrast microscopy using synthetic aperture imaging.

We implement differential interference contrast (DIC) microscopy using high-speed synthetic aperture imaging that expands the passband of coherent imaging by a factor of 2.2. For an aperture synthesized coherent image, we apply for the numerical post-processing and obtain a high-contrast DIC image for arbitrary shearing direction and bias retardation. In addition, we obtain images at different ...

متن کامل

Phase control and measurement in digital microscopy

The ongoing merger of the digital and optical components of the modern microscope is creating opportunities for new measurement techniques, along with new challenges for optical modelling. This thesis investigates several such opportunities and challenges which are particularly relevant to biomedical imaging. Fourier optics is used throughout the thesis as the underlying conceptual model, with ...

متن کامل

Differential diagnosis of pancreatic cystic masses with the quantitative analysis of spectral CT imaging: Initial results

Background: To retrospectively evaluate whether quantitative information derived from spectral imaging can improve the differential diagnosis of pancreatic cystic masses including pancreatic solid pseudopapillary epithelial neoplasms (SPENs), mucin- producing cysts and pseudocysts. Materials and Methods: From June 2015 to October 2017, 56 patients (22 pseudocysts, 18 mucin-producing cysts and 1...

متن کامل

Relationship between fracture dip angle, aperture and fluid flow in the fractured rock masses

Most of the Earth's crust contains fluids, and fractures are common throughout the upper part. They exist at a wide range of scales from micro-fractures within grains to major faults and shear zones that traverse the crust. In this paper, the stress-dependent permeability in fractured rock masses have been investigated considering the effects of nonlinear normal deformation and shear dilation o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Optics letters

دوره 32 20  شماره 

صفحات  -

تاریخ انتشار 2007