BACKGROUND This study aimed at correlating anatomical dimensions of the larynx and trachea to age and weight in a prenatal population. Endotracheal tube size determination was then proposed according to these considerations. METHODS Anatomical measurements were obtained during 150 fetal and infant postmortem examinations. The optimal endotracheal tube size was determined by three methods: clinically, by a pressure method using calibrated inextensible balloons, and anatomically by comparing the laryngotracheal perimeter to the tube perimeters. Based on these results, recommended tube sizes were calculated. RESULTS In premature babies before 37 weeks gestation, the optimal tube size according to pressure estimation was significantly greater than that determined by anatomical measurement alone. This difference was no longer valid after 40 weeks gestation. CONCLUSIONS This study identified the elasticity of laryngeal structures in premature babies, allowing intubation with tube sizes greater than predicted by anatomical measurements with an increasing injury risk located in the posterior part of the glottic plane. This elasticity disappears near 40 weeks gestation, and the injury risk then predominates in the subglottic region. These results lead the authors to recommend that the size of the endotracheal tube used in the perinatal population should be based on anatomical and experimental data to limit the injury risks.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Stabilizing Endotracheal Tube on Quality of Airway Management in Patients Hospitalized in ICU

Background: The unplanned departure of endotracheal tube is one of the main complications for endotracheal intubation. In addition to endotracheal extubation, its movement can also lead to damage to the oral cavity. Stabilizing endotracheal tube is the most important factor that can prevent unplanned departure of endotracheal tube as well as its movement. The current study was done with the aim...

متن کامل

The Effect of Instructing the Principles of Endotracheal Tube Suctioning on Knowledge and Performance of Nursing Staff Working in Neonatal Intensive Care Units in Shiraz University of Medical Sciences

Introduction: Nurses must be aware of the risks regarding endotracheal tube suctioning and should have continuing education in this field. This study was performed to assess the impact of instruction on the knowledge and performance of NICU nursing staff in Shiraz University of Medical Sciences in 2006. Methods: Fifty nurses of neonatal intensive care units participated in this quasi experimen...

متن کامل

Effect of Gargling with Honey and Lemon Water on Cough, Sore Throat, and Hoarseness Following Endotracheal Extubation: A Clinical Trial Study

 Background and purpose: Cough, hoarseness, and sore throat are complications of intubation. The aim of this study was to evaluate the effect of gargling with honey and lemon water on cough, sore throat, and hoarseness after extubation of endotracheal tube following surgery. Materials and methods: A clinical trial was carried out in 110 patients undergoing surgery in Neyshabur 22 Bahman Hospit...

متن کامل

Effect of arsenic on neural tube in mouse embryo and relation to reduced folate carrier (RFC-1)

Arsenic is an important environmental toxicant which is usually found in drinking water in inorganic form. The hypothesis tested in this investigation is; arsenic exposure causes neural tube defects (NTDs) andthese defects of the central nervous system are more likely related to folate deficiency during fetal life. In this study, sodium arsenate was administered via intraperitoneal route at a r...

متن کامل

New Metal Shield for the Endotracheal Tube during Laser Endolaryngeal Surgery

Introduction: To present and assess a newly designed autoclavable, reusable tube shield for an endotracheal tube (ETT) during laser laryngeal surgery.   Materials and Methods: This study included patients scheduled for endolaryngeal laser surgery. A carbonated stainless-steel hemisphere shield (~1.5×0.6 mm) connected to a silk thread passing through a hole in its middle near upper edge was ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Anesthesiology

دوره 104 5  شماره 

صفحات  -

تاریخ انتشار 2006