Endoscopic Electrosurgery in Patients with Cardiac Implantable Electronic Devices
نویسندگان
چکیده
BACKGROUND/AIMS Patients with cardiac implantable electronic devices (CIEDs) undergoing endoscopic electrosurgery (EE) are at a risk of electromagnetic interference (EMI). We aimed to analyze the effects of EE in CIED patients. METHODS Patients with CIED who underwent EE procedures such as snare polypectomy, endoscopic submucosal dissection (ESD), and endoscopic retrograde cholangiopancreatography (ERCP) with endoscopic sphincterotomy (EST) were retrospectively analyzed. Postprocedural symptoms as well as demographic and outpatient follow-up data were reviewed through medical records. Electrical data, including preprocedural and postprocedural arrhythmia records, were reviewed through pacemaker interrogation, 24-hour Holter monitoring, or electrocardiogram. RESULTS Fifty-nine procedures in 49 patients were analyzed. Fifty procedures were performed in 43 patients with a pacemaker, and nine were performed in six patients with an implantable cardioverter-defibrillator. There were one gastric and 44 colon snare polypectomies, five gastric and one colon ESDs, and eight ERCPs with EST. Fifty-five cases of electrical follow-up were noted, with two postprocedural changes not caused by EE. Thirty-one pacemaker interrogations had procedure recordings, with two cases of asymptomatic tachycardia. All patients were asymptomatic with no adverse events. CONCLUSIONS Our study reports no adverse events from EE in patients with CIED, suggesting that this procedure is safe. However, because of the possibility of EMI, recommendations on EE should be followed.
منابع مشابه
Is It Safe to Perform Therapeutic Endoscopic Procedures in Patients with Implanted Electronic Cardiac Devices?
As the use of cardiac implantable electronic devices (CIEDs) such as pacemakers and implantable cardioverter-defibrillators is increasing, management of those device-wearing patients with electrosurgery has attracted growing attention, not only in the area of gastroenterology, but also in other fields, including dermatology and urology. For gastroenterologists, there have been concerns about el...
متن کاملEndoscopy and implantable electronic devices.
The increasing use of implantable electronic devices such as cardiac pacemakers and neurostimulators means that they are being increasingly encountered in endoscopy departments. The electromagnetic fields generated during electrosurgery and with magnetic imaging systems have the potential to interfere with such devices. The authors present a case that highlights some of the steps necessary for ...
متن کاملElectrosurgery and implantable electronic devices: review and implications for office-based procedures.
The number of patients with implantable electronic devices (IEDs) is growing as indications for a myriad of cardiac and neurological disorders that cannot be managed using medication alone expand. These devices include gastric and cardiac pacemakers, implantable cardioverter defibrillators, cochlear implants, and a range of stimulators of the deep brain, vagal nerve, sacral nerve, phrenic nerve...
متن کاملElectrosurgery in patients with implantable electronic cardiac devices (pacemakers and defibrillators).
The electrosurgical unit is a very useful tool widely used in dermatology to treat benign and malignant skin lesions and to achieve hemostasis during surgery. However, precautions are required when this technique is used in patients with implantable electronic cardiac devices (IECD), such as pacemakers and defibrillators, because electromagnetic interference produced by the tool may cause such ...
متن کاملAnaesthetic consideration in patients with cardiac implantable electronic devices scheduled for surgery
With advances in cardiology and cardiothoracic surgery, several newer implantable cardiac devices have become common in the surgical population. Multichamber pacemakers, implanted cardiac defibrillators and ventricular assist devices are frequent in current day practice. Many of the newer implantable cardiac electronic devices are targeted at managing heart failure. While managing such patients...