Optimal tilt magnitude determination for aberration-corrected super resolution exit wave function reconstruction.
نویسندگان
چکیده
Transmission electron microscope (TEM) images recorded under tilted illumination conditions transfer higher spatial frequencies than axial images. This super resolution information transfer is highly directional in a single image, but can be extended in all directions through the use of complementary beam tilts during exit wave function reconstruction. We have determined the optimal experimental tilt magnitude for aperture synthesis in an aberration-corrected TEM. It is shown that electron-optical aberration correction allows the use of larger tilt angles and reduces the constraints that are imposed on experimental data acquisition in an uncorrected microscope. We demonstrate that, in many cases, the resolution improvement achievable is now limited by the sample and not by instrumental parameters. An exit wave function is presented that has been successfully reconstructed from a dataset of aberration-corrected images, including images acquired at a beam tilt of 18 mrad, which clearly demonstrates a resolution improvement from 0.11 nm to better than 0.08 nm at 200 kV.
منابع مشابه
Atomic Resolution Imaging of Halide Perovskites.
The radiation-sensitive nature of halide perovskites has hindered structural studies at the atomic scale. We overcome this obstacle by applying low dose-rate in-line holography, which combines aberration-corrected high-resolution transmission electron microscopy with exit-wave reconstruction. This technique successfully yields the genuine atomic structure of ultrathin two-dimensional CsPbBr3 ha...
متن کاملAberration Corrected Electron Microscopy: Prospects and Applications
Aberration correction in the TEM is now relatively well established with more than 20 corrected instruments installed worldwide. This paper will review these instrumental advances and will also describe the underlying theory and computation required to optimise data acquisition and interpret aberration corrected images. Finally the combination of direct electron optical correction and indirect ...
متن کاملSpherical aberration correction in tandem with exit-plane wave function reconstruction: interlocking tools for the atomic scale imaging of lattice defects in GaAs.
With the availability of resolution boosting and delocalization minimizing techniques, for example, spherical aberration correction and exit-plane wave function reconstruction, high-resolution transmission electron microscopy is drawing to a breakthrough with respect to the atomic-scale imaging of common semiconductor materials. In the present study, we apply a combination of these two state-of...
متن کاملPhase retrieval from image intensities: why does exit wave restoration using IWFR work so well?
The iterative wave function reconstruction (IWFR) is one type of in-line holography and retrieves a complex wave function from a set of through-focus images. We have verified that the IWFR provides an extremely good estimate of an atomic-resolution exit wave function (EWF) simply from the Fourier transforms of observed intensities. Thus, the first guess of the EWF using only five images gives a...
متن کاملAberration corrected TEM: current status and future prospects
Aberration correction leads to a substantial improvement in the interpretable resolution of Transmission Electron Microscopes. Electron optical correctors based on two strong hexapole elements linked through a round lens transfer doublet enables direct correction of all axial aberrations to third order. Subsequent, indirect computational analysis of a focal or tilt series of images offers the p...