The Zeplin-iii Dark Matter Detector: Instrument Design, Manufacture and Commissioning

نویسندگان

  • D. Davidge
  • R. J. Hollingworth
  • V. A. Kudryavtsev
  • V. N. Lebedenko
  • G. G. Nicklin
  • S. M. Paling
  • J. J. Quenby
  • N. J. C. Spooner
چکیده

We present details of the technical design and manufacture of the ZEPLIN-III dark matter experiment. ZEPLIN-III is a two-phase xenon detector which measures both the scintillation light and the ionisation charge generated in the liquid by interacting particles and radiation. The instrument design is driven by both the physics requirements and by the technology requirements surrounding the use of liquid xenon. These include considerations of key performance parameters, such as the efficiency of scintillation light collection, restrictions placed on the use of materials to control the inherent radioactivity levels, attainment of high vacuum levels and chemical contamination control. The successful solution has involved a number of novel design and manufacturing features which will be of specific use to future generations of direct dark matter search experiments as they struggle with similar and progressively more demanding requirements.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ar X iv : a st ro - p h / 06 05 50 0 v 1 1 9 M ay 2 00 6 The ZEPLIN - III dark matter detector : instrument design , manufacture and commissioning

We present details of the technical design and manufacture of the ZEPLIN-III dark matter experiment. ZEPLIN-III is a two-phase xenon detector which measures both the scintillation light and the ionisation charge generated in the liquid by interacting particles and radiation. The instrument design is driven by both the physics requirements and by the technology requirements surrounding the use o...

متن کامل

The ZEPLIN-III dark matter detector: performance study using an end-to-end simulation tool

We present results from a GEANT4-based Monte Carlo tool for end-to-end simulations of the ZEPLIN-III dark matter experiment. ZEPLIN-III is a two-phase detector which measures both the scintillation light and the ionisation charge generated in liquid xenon by interacting particles and radiation. The software models the instrument response to radioactive backgrounds and calibration sources, inclu...

متن کامل

The Zeplin Ii Dark Matter Detector: Data Acquisition System and Data Reduction the Zeplin Ii Dark Matter Detector: Data Acquisition System and Data Reduction

ZEPLIN II is a two-phase (liquid/gas) xenon dark matter detector searching for WIMP-nucleon interactions. In this paper we describe the data acquisition system used to record the data from ZEPLIN II and the reduction procedures which parameterise the data for subsequent analysis.

متن کامل

Dark Matter Experiments at Boulby Mine

The Boulby Dark Matter Collaboration (BDMC) is running several experiments for particle (WIMP) dark matter search in the Underground Boulby Laboratory. These include a liquid xenon detector (ZEPLIN I) and a low pressure gas TPC with directional sensitivity (DRIFT I). Next stage double-phase xenon detectors ZEPLIN II and ZEPLIN III, and a new TPC DRIFT II will be installed at Boulby in a few mon...

متن کامل

The ZEPLIN II dark matter detector : data acquisition system and data reduction

ZEPLIN II is a two-phase (liquid/gas) xenon dark matter detector searching for WIMP-nucleon interactions. In this paper we describe the data acquisition system used to record the data from ZEPLIN II and the reduction procedures which parameterise the data for subsequent analysis.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015