Goldmann Applanation Tonometry: Using a Red-Free Filter for Mass Screening

نویسندگان

  • Shahram BAMDAD
  • Yalda VATAN
چکیده

This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial 3.0 License (CC BY-NC 3.0), which allows users to read, copy, distribute and make derivative works for non-commercial purposes from the material, as long as the author of the original work is cited properly. Goldmann applanation tonometry is the gold standard medical instrument for the measurement of intraocular pressure (IOP) for a long time (1, 2). Fluorescein staining (either using a fluorescein-impregnated paper strip or a fluorescein solution) is often conducted prior to IOP measurement. However, following the application of fluorescein, patients often experience a stinging sensation, eyelid discoloration, mucus discharge, or a combination of these side effects. To avoid these side effects, and to thereby improve patient comfort, several researchers have suggested that IOP measurement should be conducted without fluorescein. However, there is no consensus on this proposal, and some of the researchers have proposed using a reduced quantity of fluorescein, while others have suggested completely eliminating it (3,4,6). Au et al. measured the IOP of 30 subjects using Goldmann applanation tonometry with a small quantity of fluorescein, and they found that this technique was an effective and precise method for measuring IOP prior to fitting soft contact lenses (3). In addition, a recent cross-sectional study by Ghoneim et al. measured the IOP of 250 patients, first with fluorescein (with cobalt blue light) and then without fluorescein (with red-free light). There was no significant difference in the measured IOP between the two measurement methods. The mean IOP using the technique without fluorescein was 15.23 ± 3.3 mmHg, and that associated with the use of fluorescein was 12.8215.78 ± 2.43.7 mmHg (4). The authors concluded that IOP measurement using Goldmann applanation tonometry without fluorescein and with a red-free filter resulted in accurate IOP measurements (4). In contrast, a 1981 study by Bright et al. of 100 patients found that the mean IOP measured without fluorescein

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative evaluation of intraocular pressure with an air-puff tonometer versus a Goldmann applanation tonometer

PURPOSE Tonometry, or measurement of intraocular pressure (IOP), is one of the most important examination procedures in ophthalmic clinics, and IOP is an important parameter in the diagnosis of glaucoma. Because there are numerous types of tonometer available, it is important to evaluate the differences in readings between different tonometers. Goldmann applanation tonometers (GATs) and noncont...

متن کامل

Applanation tonometry: a comparison of the Perkins handheld and Goldmann slit lamp-mounted methods

PURPOSE To compare intraocular pressure (IOP) measurements, taken using Perkins applanation tonometry (PAT) and Goldmann applanation tonometry (GAT). METHODS 100 eyes of 100 patients underwent Perkins and Goldmann applanation tonometry, with a randomized order of modality, performed by a masked observer. The right eye was measured, for all subjects, and the data used in statistical analysis. ...

متن کامل

Pressure phosphene tonometry versus Goldmann applanation tonometry for measuring intraocular pressure before and after LASIK.

PURPOSE To compare pressure phosphene tonometry with Goldmann applanation tonometry for measuring intraocular pressure (IOP) before and after LASIK. METHODS Forty-three (18 men and 25 women) consecutive healthy patients underwent complete pre- and postoperative LASIK ophthalmologic assessments including manifest and cycloplegic refraction, keratometry, and central corneal thickness. Three rep...

متن کامل

Comparison of intraocular pressure measurement between rebound, non-contact and Goldmann applanation tonometry in treated glaucoma patients.

BACKGROUND To compare the intraocular pressure readings obtained with the iCare rebound tonometer and the 7CR non-contact tonometer with those measured by Goldmann applanation tonometry in treated glaucoma patients. DESIGN A prospective, cross-sectional study was conducted in a private tertiary glaucoma clinic. PARTICIPANTS OR SAMPLES One hundred nine (54 males : 55 females) patients includ...

متن کامل

Comparison of different intraocular pressure measurement techniques in normal eyes, post surface and post lamellar refractive surgery

BACKGROUND The purpose of this study was to determine the accuracy of intraocular pressure (IOP) measurement after laser in situ keratomileusis (LASIK) or epithelial laser in situ keratomileusis (Epi)-LASIK using Goldmann applanation tonometry, air puff tonometry, ocular response analyzer corneal compensated IOP (ORA IOPcc) and Pentacam corrected IOP. METHODS A prospective comparative clinica...

متن کامل