The biomechanical advantages of bilateral lumbo-iliac fixation in unilateral comminuted sacral fractures without sacroiliac screw safe channel
نویسندگان
چکیده
BACKGROUND The aim of this study was to compare the biomechanical characteristics between bilateral and unilateral lumbo-iliac fixation in unilateral comminuted sacral fractures (USF) by finite element analysis. METHODS A 3-dimensional finite element model of unilateral sacral fractures was simulated. Three kinds of implants were instrumented into the model, including the unilateral lumbopelvic fixation (ULF), bilateral lumbopelvic fixation (BLF), and unilateral iliac fixation with bilateral lumbar pedicle screws (UBF). Loads of compression and rotation were distributed to the superior endplate of L3. To evaluate the biomechanical properties, the construct stiffness, the micromotion of the fractures, the stress distribution of implants, and the balance of hemilumbar vertebra are recorded and analyzed. RESULTS The highest construct stiffness was provided by BLF. In BLF model, the displacement between iliums was only 0.009 mm (compressional) and 0.001 mm (rotational), which was less than that under normal condition (0.02 mm). The maximum von Misses stress of implants appeared on the UBF. By using unilateral fixation, the L4 endured obvious imbalance on bilateral hemivertebra. A marked difference was exposed in BLF and UBF models, and the equilibrium of stress and activity was shown. CONCLUSION From the finite element view, the stability of ULF is insufficient to reconstruct the posterior pelvic ring. Furthermore, the unilateral fixation may lead to imbalance of lumbar vertebra and pelvis. On the contrary, the BLF can provide satisfied stability and lumbar balance.
منابع مشابه
Spinopelvic Fixation of Sacroiliac Joint Fractures and Fracture-Dislocations: A Clinical 8 Years Follow-Up Study
Background: Pelvic ring injuries and sacroiliac dislocations have significant impacts on patient’s quality of life. Several techniques have been described for posterior pelvic fixation. The current study has been designed to evaluate the spinopelvic method of fixation for sacroiliac fractures and fracture-dislocations. Methods: Between January 2006 and December 2014, 14 patients with sacroi...
متن کاملSurgical treatment in sacral fractures and traumatic spinopelvic instabilities.
AIM Sacral fractures are generally seen together with pelvic ring fractures. They can also develop in isolated form rarely. Instability is observed in these fractures in rates reaching 30%. MATERIAL AND METHODS Spinopelvic stabilization was applied to 10 cases with pelvic fractures together with sacral fractures and spinopelvic instability. Two cases were treated with adductive screws extendi...
متن کاملCT-Guided Screw Fixation of Vertical Sacral Fractures in Local Anaesthesia Using a Standard CT CT-kontrollierte Schraubenosteosynthese von vertikalen Frakturen des hinteren Beckenringes in Lokalanästhesie
Purpose: To evaluate time efficiency, radiation dose, precision and complications of percutaneous iliosacral screw placement under CT-guidance in local anaesthesia. Material and Methods: Retrospective analysis of 143 interventions in 135 patients during a period of 42 months. Implant failures could be evaluated in 85/182 screws and bony healing or refracturing in 46/182 screws. Results: A total...
متن کاملUnilateral and bilateral sacropelvic fixation result in similar construct biomechanics.
STUDY DESIGN In vitro biomechanical investigation of lumbosacropelvic spinal instrumentation. OBJECTIVE Determine whether unilateral iliac fixation, with or without an L6 to S1 interbody graft, provides equivalent biomechanical stability compared with bilateral iliac fixation. SUMMARY OF BACKGROUND DATA Recent clinical evidence has shown improved clinical outcomes of unilateral iliac fixati...
متن کاملPercutaneous Ilio-Sacral Screw Fixation in Supine Position under Fluoroscopy Guidance.
BACKGROUND Pelvic ring disruption when treated conservatively can be associated with prolonged hospital stay and immobilization, mal-union, chronic pain, limb length discrepancy if they are treated conservatively. Open reduction and fixation in an already compromised soft tissue and hemodynamically unstable patient causes more soft tissue injury, heamatoma, infection and neurovascular injury. P...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 95 شماره
صفحات -
تاریخ انتشار 2016