Evidence of Cooper pair pumping with combined flux and voltage control

نویسندگان

  • Antti O. Niskanen
  • Jani M. Kivioja
  • Heikki Seppä
  • Jukka P. Pekola
چکیده

We have experimentally demonstrated pumping of Cooper pairs in a single-island mesoscopic structure. The island was connected to leads through SQUID (Superconducting Quantum Interference Device) loops. Synchronized flux and voltage signals were applied whereby the Josephson energies of the SQUIDs and the gate charge were tuned adiabatically. From the current-voltage characteristics one can see that the pumped current increases in 1e steps which is due to quasiparticle poisoning on the measurement time scale, but we argue that the transport of charge is due to Cooper pairs.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Decoherence in adiabatic quantum evolution: application to cooper pair pumping.

One of the challenges of adiabatic control theory is the proper inclusion of the effects of dissipation. Here we study the adiabatic dynamics of an open two-level quantum system deriving a generalized master equation to consistently account for the combined action of the driving and dissipation. We demonstrate that in the zero-temperature limit the ground state dynamics is not affected by envir...

متن کامل

A Combined Vector and Direct Power Control for AC/DC/AC Converters in DFIG Based Wind Turbine

The doubly-fed generators (DFIG) have clear superiority for the applications of large capacity and limited-range speed control case due to the partially rated inverter, lower cost and high reliability. These characteristics enable the doubly-fed wound rotor induction machine to have vast applications in wind-driven generation.In this paper Combined Vector and direct power control (CVDPC) strate...

متن کامل

Virtual Flux Based Direct Power Control on Vienna Rectifier

This paper proposes the virtual flux based direct power control for Vienna rectifier. No need for the input voltage sensors, the current regulation loop and PWM voltage modulation block along with the active and reactive power decoupling are some of the salient advantages of this method that make it suitable for controlling the conventional active rectifiers. However, due to the three-level nat...

متن کامل

A Novel High-Performance Field-Weakening Control for Axial Flux-Switching Permanent-Magnet Motor

By combining the field-weakening control principle of a new axial flux-switching permanent-magnet motor (AFFSSPM) with the space vector pulse width modulation (SVPWM) and maximum torque per voltage (MTPV) control principle, a novel field-weakening control strategy for AFFSSPM is proposed in this paper. In the first stage of the field-weakening, the difference between the reference voltage updat...

متن کامل

Control of Open Quantum Systems

Aalto University, P.O. Box 11000, FI-00076 Aalto www.aalto.fi Author Juha Salmilehto Name of the doctoral dissertation Control of Open Quantum Systems Publisher School of Science Unit Department of Applied Physics Series Aalto University publication series DOCTORAL DISSERTATIONS 102/2014 Field of research Engineering Physics, Theoretical and Computational Physics Manuscript submitted 13 May 201...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004