In Vitro Comparative Biocompatibility Testing of Carbofilm Coated and Uncoated Polyetherimide for Cardiovascular Application

نویسندگان

  • M. Bosetti
  • L. Nicolais
  • L. Ambrosio
  • M. Cannas
  • Mario Cannas
چکیده

When blood contacts the surface of a material, several processes take place including the activation of coagulation and immune systems. The aim of this work is to study in vitro the biological reactions seen from the point of view ofhemocompatibility and cytocompatibility of a new polymer suggested as an artificial surface for cardiovascular applications: CarbofiJm® coated polyetherimide (C®PEI) in comparison to polyetherimide (PEl) , the uncoated form. PEl and C®PEI showed no signs of acute cytotoxicity although following long term incubation with PEl cytotoxicity was somewhat increased; both materials supported good endothelial cell adhesion with a higher level of cell proliferation on the coated form. No significant difference was detected in the activation of the inflammatory response and in thrombogenicity tested by assay of prostaglandin E2 (PGE2) and tromboxane B2 (TXB2) respectively, following incubation of the biomaterials with platelet-rich plasma (PRP). Complement activation assessed by sodium dodecy! sulfate polyacrylamide gel electrophoresis (SDS-PAGE)/Westem Blot analysis of both contacting plasma and protein which adsorbed on the surface of the polymers showed both materials to be activators of complement. In conclusion, Carbofilm® coating, showing lower cytotoxic activity and higher endothelial cell growth in comparison with uncoated material , seems to increase PEl compatibility.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vitro biocompatibility of low and medium molecular weight chitosan–coated Fe3O4 nanoparticles

Objective(S): The chitosan - Fe3O4 core - shell nanoparticles were synthesized. The nanoparticles should be coated properly in the shape of core-shell, so that they remain hidden from the body's immune system after coating. Effects of different molecular weight in coating were investigated. Methods: Nanoparticles coated with low and ...

متن کامل

In vitro behavior of silk fibroin-coated calcium magnesium silicate scaffolds

Bioceramic scaffolds such as silicate bioceramics have been widely used for bone tissue engineering. However, their high degradation rate, low mechanical strength and surface instability are main challenges compromising their bioactivity and cytocompatibility which further negatively affect the cell growth and attachment. In this study, we have investigated the effects of silk fibroin coating o...

متن کامل

Characterization and In Vitro and In Vivo Assessment of a Novel Cellulose Acetate-Coated Mg-Based Alloy for Orthopedic Applications

Despite their good biocompatibility and adequate mechanical behavior, the main limitation of Mg alloys might be their high degradation rates in a physiological environment. In this study, a novel Mg-based alloy exhibiting an elastic modulus E = 42 GPa, Mg-1Ca-0.2Mn-0.6Zr, was synthesized and thermo-mechanically processed. In order to improve its performance as a temporary bone implant, a coatin...

متن کامل

Biocompatibility and mechanical properties of diamond-like coatings on cobalt-chromium-molybdenum steel and titanium-aluminum-vanadium biomedical alloys.

Diamond-like carbon (DLC) films are favored for wear components because of diamond-like hardness, low friction, low wear, and high corrosion resistance (Schultz et al., Mat-wiss u Werkstofftech 2004;35:924-928; Lappalainen et al., J Biomed Mater Res B Appl Biomater 2003;66B:410-413; Tiainen, Diam Relat Mater 2001;10:153-160). Several studies have demonstrated their inertness, nontoxicity, and t...

متن کامل

Co3O4 spinel protection coating for solid oxide fuel cell interconnect application

In the present study, electrophoretic deposition (EPD) method in different electric fields (30 – 300 V / cm) was used to apply Co3O4 spinel coating to SUS 430 as SOFC interconnect. The coated and uncoated specimens were pre-sintered in air at 800 and 900 °C for 3 h followed by cyclic oxidation at 700 and 800 °C for 500 h, respectively. X-ray diffraction analysis (XRD), Scanning Electron Microsc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017