Phantom-based quality assurance measurements in B-mode ultrasound

نویسندگان

  • Vilma Mannila
  • Outi Sipilä
چکیده

BACKGROUND Recommended phantom-based quality assurance measurements in B-mode ultrasound (US) may be tedious. For the purpose of cost-effective US quality assurance it is important to evaluate measurements that effectively reflect the quality of US scanner. PURPOSE To find out which recommended phantom-based quality assurance measurements are effective in detecting dead or weak transducer elements or channels in US scanners when visual image analysis and manual measurements are used. MATERIAL AND METHODS Altogether 66 transducers from 33 US scanners were measured using a general purpose phantom and a transducer tester. The measurements were divided into two groups. Group I consisted of phantom-based uniformity measurement, imaging the air with a clean transducer (air image) and measuring the transducer with the transducer tester, and group II of phantom-based measurements of depth of penetration, beam profile, near field, axial and lateral resolution, and vertical and horizontal distance accuracy. The group II measurements were compared to group I measurements. RESULTS With group I measurements, the results with 20% of the transducers were found defective. With 35% of the transducers the results were considered defective in group II measurements. Concurrent flaws in both groups were found with 11% of the transducers. CONCLUSION Phantom-based measurements of depth of penetration, beam profile, near field, axial and lateral resolution, and vertical and horizontal distance accuracy did not consistently detect dead or weak transducer elements or channels in US scanners.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparative Study on the Influence of Probe Placement on Quality Assurance Measurements in B-mode Ultrasound by Means of Ultrasound Phantoms

To check or to prevent failures in ultrasound medical systems, some tests should be scheduled for both clinical suitability and technical functionality evaluation: among them, image quality assurance tests performed by technicians through ultrasound phantoms are widespread today and their results depend on issues related to scanner settings as well as phantom features and operator experience. I...

متن کامل

Ultrasound Equipment Quality Assurance

Components of an Ultrasound Quality Assurance Program 257 Quality Assurance and Preventive Maintenance 257 Tissue-Mimicking Phantoms 257 Tissue Properties Represented in Phantoms 257 Typical Quality Assurance Phantom Design 257 Cautions About Phantom Desiccation 258 Basic Quality Control Tests 259 Visual Inspection 259 Transducer Choice 259 System Sensitivity 260 Photography and Gray-Scale Hard...

متن کامل

Diagnostic Ultrasound Scanner Quality Assurance

Medical Physics at CancerCare Manitoba has developed its own ultrasound phantom. The following table is intended as a quick reference guide when performing the quality assurance measurements. Instructions Limits Record Items Required ultrasound contrast-detail phantom degassed water or coupling gel paper towels for clean up (optional) lab stand and clamp to hold probe Physical check: 1. probe s...

متن کامل

Daily quality assurance phantom for ultrasound image guided radiation therapy

A simple phantom was designed, constructed, tested, and clinically implemented for daily quality assurance (QA) of an ultrasound-image-guided radiation therapy (US-IGRT) system, the Restitu Ultrasound system (Resonant Medical, Montreal, QC). The phantom consists of a high signal echogenic background gel surrounding a low signal hypoechoic egg-shaped target. Daily QA checks involve ultrasound im...

متن کامل

Comparison of ultrasound quality assurance phantom measurements from matched and mixed scanner‐transducer combinations

Our goal in this work was to compare the results of common phantom tests made using matched and mixed ultrasound (US) scanner-transducer combinations. Sets of common US quality assurance (QA) measurements were made using matched US scanner-transducer combinations (i.e., transducers purchased for use with a particular scanner), as well as unmatched (mixed) combinations. Measurements of vertical ...

متن کامل