Radiation dose associated with coronary CT angiography and invasive coronary angiography: an experimental study of the effect of dose-saving strategies.

نویسندگان

  • Akmal Sabarudin
  • Zhonghua Sun
  • Kwan-Hoong Ng
چکیده

This study was conducted on a human anthropomorphic phantom to investigate the effective dose and entrance skin dose (ESD) in selected radiosensitive organs through invasive and computed tomography (CT) coronary angiography procedures using different dose-saving techniques. The effective dose was calculated as 2.49, 3.35 and 9.62 mSv, respectively, corresponding to three coronary CT angiography protocols, including prospective ECG gating and retrospective ECG gating with and without tube current modulation. In comparison, the effective dose was calculated as 7.26, 6.35, 5.58 and 4.71 mSv at four different magnifications acquired with invasive coronary angiography. The highest ESD was measured in the breast during the coronary CT angiography and in the thyroid gland during invasive coronary angiography. Although invasive coronary angiography produces lower radiation dose than coronary CT angiography, application of modified techniques in both CT and invasive coronary angiography is recommended in clinical practice for radiation dose reduction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Breast Radiation Protection in Coronary Angiography

Introduction: Coronary angiography (CA) is an interventional diagnostic procedure to assess cardiovascular disease. CA is performed using dedicated fluoroscopic systems equipped with either flat detector or image intensifier. There is an increase in the number of CA annually. Reducing the radiation exposure in the CA is essential, especially due to high fluoroscopy time. In ord...

متن کامل

Evaluation of cancer risk of the patients undergoing coronary angiography in Yazd, Iran

Background: Coronary angiography is a commonly performed diagnostic procedure with life saving benefits for the patient. However, this procedure involves relatively high radiation dose. The purpose of this study was to determine the average effective dose of patients undergoing coronary angiography and to estimate the associated radiation risk in terms of fatal malignancy. Materials an...

متن کامل

Coronary CT angiography: current status and continuing challenges.

Coronary CT angiography has been increasingly used in the diagnosis of coronary artery disease owing to rapid technological developments, which are reflected in the improved spatial and temporal resolution of the images. High diagnostic accuracy has been achieved with multislice CT scanners (64 slice and higher), and in selected patients coronary CT angiography is regarded as a reliable alterna...

متن کامل

Patient dose values during interventional cardiology examinations in Yazd hospital, Iran

Background: The number of interventional cardiology (IC) procedures has increased rapidly. coronary angiography (CA) and percutaneous transluminal coronary angioplasty (PTCA) are now widely performed as a matter of routine, and they are considered safe procedures for experienced cardiologists. However, it is also known that these procedures are associated with high radiation doses due to long f...

متن کامل

حفاظت پرتویی بیماران در سی تی آنژیوگرافی قلب

Introduction: Cardiac CT (Computed Tomography) angiography applies as a pre-exam method for evaluating the patients with medical problems in their cardiac arteries. Due to the high delivered dose in this imaging method, dose reduction techniques and imaging strategies that serve the images quality with minimum patient dose are the subjects for investigation and research studies. This study will...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiation protection dosimetry

دوره 150 2  شماره 

صفحات  -

تاریخ انتشار 2012