Accelerator Mass Spectrometry Targets of Submilligram Carbonaceous Samples Using the High-Throughput Zn Reduction Method

نویسندگان

  • Seung-Hyun Kim
  • Peter B. Kelly
  • Andrew J. Clifford
چکیده

The high-throughput Zn reduction method was developed and optimized for various biological/biomedical accelerator mass spectrometry (AMS) applications of mg of C size samples. However, high levels of background carbon from the high-throughput Zn reduction method were not suitable for sub-mg of C size samples in environmental, geochronology, and biological/biomedical AMS applications. This study investigated the effect of background carbon mass (mc) and background 14C level (Fc) from the high-throughput Zn reduction method. Background mc was 0.011 mg of C and background Fc was 1.5445. Background subtraction, two-component mixing, and expanded formulas were used for background correction. All three formulas accurately corrected for backgrounds to 0.025 mg of C in the aerosol standard (NIST SRM 1648a). Only the background subtraction and the two-component mixing formulas accurately corrected for backgrounds to 0.1 mg of C in the IAEA-C6 and -C7 standards. After the background corrections, our high-throughput Zn reduction method was suitable for biological (diet)/biomedical (drug) and environmental (fine particulate matter) applications of sub-mg of C samples (> or = 0.1 mg of C) in keeping with a balance between throughput (270 samples/day/analyst) and sensitivity/accuracy/precision of AMS measurement. The development of a high-throughput method for examination of > or = 0.1 mg of C size samples opens up a range of applications for 14C AMS studies. While other methods do exist for > or = 0.1 mg of C size samples, the low throughput has made them cost prohibitive for many applications.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biological/Biomedical Accelerator Mass Spectrometry Targets. 1. Optimizing the CO2 Reduction Step Using Zinc Dust

Biological and biomedical applications of accelerator mass spectrometry (AMS) use isotope ratio mass spectrometry to quantify minute amounts of long-lived radioisotopes such as (14)C. AMS target preparation involves first the oxidation of carbon (in sample of interest) to CO 2 and second the reduction of CO 2 to filamentous, fluffy, fuzzy, or firm graphite-like substances that coat a -400-mesh ...

متن کامل

Quality of Graphite Target for Biological/Biomedical/Environmental Applications of 14C-Accelerator Mass Spectrometry

Catalytic graphitization for (14)C-accelerator mass spectrometry ((14)C-AMS) produced various forms of elemental carbon. Our high-throughput Zn reduction method (C/Fe = 1:5, 500 degrees C, 3 h) produced the AMS target of graphite-coated iron powder (GCIP), a mix of nongraphitic carbon and Fe(3)C. Crystallinity of the AMS targets of GCIP (nongraphitic carbon) was increased to turbostratic carbon...

متن کامل

Design, Construction and Calibration of a Laser Ionization Time-of-Flight Mass Spectrometer

A time-of-flight mass spectrometer (TOF-MS) developed in our laboratory at Isfahan University of Technology is described here. The TOF-MS instrument uses laser as the ionization source which provides an opportunity to investigate the ions formed in laser ablation or desorption. The TOF-MS has an ionization chamber containing an accelerator and an ion lens to focus the ions into a one meter line...

متن کامل

Measurement of the Trace Elements Cu, Zn, Fe, and Mg and the Ultratrace Elements Cd, Co, Mn, and Pb in Limited Quantity Human Plasma and Serum Samples by Inductively Coupled Plasma-Mass Spectrometry

In public health studies limited volumes of blood are often collected and stored for future hypothesis testing. Archived samples are irreplaceable and therefore it is valuable to develop analytical techniques that require minimal sample volume. This work describes the measurement of trace elements Mg, Cu, Fe, Zn and ultratrace elements Cd, Co, Mn, Pb in limited quantity (150 μL) human serum or ...

متن کامل

Development of a novel high-throughput analytical methodology, multiple injection method, for quantitative analysis in drug metabolism and pharmacokinetic studies using liquid chromatography with tandem mass spectrometry.

In this study, we developed a novel methodology, multiple injection method (MIM), for higher-throughput screening of compounds by liquid chromatography-tandem mass spectrometry (LC-MS/MS). MIM involves continuous injections of multiple samples containing a different compound respectively into the column, and then temporarily trapping of analytes at the column head in high-pressure liquid chroma...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical Chemistry

دوره 81  شماره 