Update on hybrid conjugate-view SPECT tumor dosimetry and response in 131I-tositumomab therapy of previously untreated lymphoma patients.
نویسندگان
چکیده
UNLABELLED A study of the use of (131)I-labeled tositumomab, preceded by an unlabeled tositumomab predose, for therapy of 76 previously untreated non-Hodgkin's lymphoma patients has been completed at the University of Michigan. Fifty-two of the 76 treated patients were imaged once during therapy with SPECT to assist in dosimetric estimation. In this article, the patient's average tumor dose, estimated by a hybrid method using that SPECT, is compared with the same statistic estimated by pretherapy conjugate views. METHODS The SPECT activity-quantification procedure used 3-dimensional CT-to-SPECT image registration. Daily pretherapy conjugate-view images provided the shape of the time-activity curve for the hybrid dose estimation. RESULTS With the hybrid method, the mean of the patient's average tumor dose over 8 patients using only their axillary tumors (162 cGy) was very significantly lower (P < 0.0001) than the mean over 47 patients using only their evaluated chest, abdominal, and pelvic tumors (624 cGy) for unknown reasons. Excluding axillary tumors as a best case for prediction, there still was considerable overlap in the distribution of a patient's average tumor dose over 38 patients who went on to a complete response (CR) and that from 9 patients who went on to a partial response (PR) using either method. However, a high value of the patient's average tumor dose was correctly associated with a CR for 15 of 16 patients (94%) with hybrid SPECT and for 9 of 12 patients (75%) with conjugate views. Also, the mean of the patient's average tumor dose for the CR patients was larger than the mean for PR patients; the P value was 0.18 with hybrid SPECT and 0.25 with conjugate views. A multiple logistic regression analysis combining the dose, tumor burden, and level of lactate dehydrogenase as explanatory variables for response did not yield statistical significance with either method. CONCLUSION Patients with evaluated tumors that receive the highest tumor radiation dose are most likely to achieve a CR. Dosimetry based on a combination of pretherapy conjugate views and intratherapy SPECT provides somewhat better correspondence between the patient's average tumor dose and his or her degree of response compared with dosimetry from pretherapy conjugate views alone. Statistical significance for the correspondence is not reached either with the dosimetric method or with either method in combination with the tumor burden and level of lactate dehydrogenase.
منابع مشابه
Initial results for Hybrid SPECT--conjugate-view tumor dosimetry in 131I-anti-B1 antibody therapy of previously untreated patients with lymphoma.
UNLABELLED A study of the use of 131I-labeled anti-B1 monoclonal antibody, proceeded by an unlabeled predose, for therapy of previously untreated non-Hodgkin's lymphoma patients has recently been completed at the University of Michigan, Ann Arbor. More than half of the patients treated were imaged intratherapy with SPECT to separate apparently large tumors, unresolved by conjugate views, into i...
متن کاملEighth Conference on Radioimmunodetection and Radioimmunotherapy of Cancer Supplement to Cancer Volume Reduction versus Radiation Dose for Tumors in Previously Untreated Lymphoma Patients Who Received Iodine-131 Tositumomab Therapy Conjugate Views Compared with a Hybrid Method
Received October 31, 2001; accepted November 14, 2001. BACKGROUND. A Phase II study of previously untreated patients with malignant low grade follicular lymphoma given a combination of unlabeled tositumomab and tositumomab labeled with iodine-131 has recently been completed. The responses of these patients have been characterized, and for some of them tumor dosimetry during therapy has been est...
متن کاملUse of integrated SPECT/CT imaging for tumor dosimetry in I-131 radioimmunotherapy: a pilot patient study.
Integrated systems combining functional (single-photon emission computed tomography; SPECT) imaging with anatomic (computed tomography; CT) imaging have the potential to greatly improve the accuracy of dose estimation in radionuclide therapy. In this article, we present the methodology for highly patient-specific tumor dosimetry by utilizing such a system and apply it to a pilot study of 4 foll...
متن کاملPatient-specific, 3-dimensional dosimetry in non-Hodgkin's lymphoma patients treated with 131I-anti-B1 antibody: assessment of tumor dose-response.
UNLABELLED A comprehensive, SPECT-based, patient-specific 3-dimensional (3D) dosimetry analysis has been performed using 3D-ID, a previously developed software package. The role of the total-body tumor burden, individual lesion size, tumor absorbed dose, and the spatial distribution of the absorbed dose on response and on the time course of tumor shrinkage has been examined in patients with lym...
متن کاملA phase I/II clinical trial for adult recurrent glioma using 131i-tm-601, an iodinated peptide derived from scorpion venom
131I-TM-601 is a 36-amino acid peptide, called chlorotoxin (TM-601), derived from scorpion venom labeled with I-131. TM-601 binds a receptor on the surface of tumor cells, and not on normal cells. A single dose of 131I-TM-601 administered intracranially to human xenografted mouse models of glioma has been shown to extend survival up to 269% in multiple studies. 131I-TM-601 is in a multi-center ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of nuclear medicine : official publication, Society of Nuclear Medicine
دوره 44 3 شماره
صفحات -
تاریخ انتشار 2003