What technique should I use to measure cardiac output?

نویسندگان

  • Christoph K Hofer
  • Michael T Ganter
  • Andreas Zollinger
چکیده

PURPOSE OF REVIEW Several less invasive cardiac output monitoring techniques are now commercially available and have the potential to replace the pulmonary artery catheter under certain clinical circumstances. The aim of this review is to give a synopsis of the currently available cardiac output measurement methods. This information should help in selecting the appropriate technique in a particular clinical setting. RECENT FINDINGS An overview is given of the currently available techniques for cardiac output monitoring. Recent validation studies demonstrate that pulse wave analysis may be used reliably as an alternative to the pulmonary artery catheter in different clinical settings. The use of transesophageal echocardiography and Doppler measurements is limited due to high operator dependency, the partial carbon dioxide rebreathing technique should be applied in a precisely defined clinical setting to mechanically ventilated patients only, and pulsed dye densitometry as well as the bioimpedance technique are currently primarily applied in an investigational setting. SUMMARY Less invasive cardiac output monitoring techniques may replace the pulmonary artery catheter in different clinical settings considering the specific properties of these techniques. The pulmonary artery catheter, however, may still be recommended for cardiac output measurement in specific clinical situations when monitoring of pulmonary artery pressures is desirable.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid Diagnosis of Acute Myocardial Infarction

To improve the specificity of biochemical markers of myocardial infarction (MI) a method to measure cardiac troponin-I (CTn-I) was developed. CTn-I is a protein unique to cardiac muscle and is released after MI. Consecutive 150 patients admitted to the coronary care unit was studied. Value of CTn-I was determined in all samples. CTn-I concentration in the MI patients group was increased com...

متن کامل

Why measure cardiac output?

Although cardiac output is a primary determinant of global O2 transport there are no absolute values that reflect circulatory adequacy, though very low values are of negative prognostic use. There is no agreement as to what constitutes a clinically relevant change in cardiac output. A recent clinical trial suggests that early goal-directed therapy aimed at increasing cardiac output improves sur...

متن کامل

Use of Follicular Output Rate to Predict Intracytoplasmic Sperm Injection Outcome

Objective The measurement of follicular output rate (FORT) has been proposed as a good indicator for evaluating follicular response to the exogenous recombinant folliclestimulating hormone (rFSH). This places FORT as a promising qualitative marker for ovarian function. The objective of the study was to determine FORT as a predictor of oocyte competence, embryo quality and clinical pregnancy aft...

متن کامل

Evaluation of the Effect of Atenolol Induced Depression in Cardiac Output on Its Own Excretion through Urine Analysis

The role of Pharmacist in making the therapeutic decisions for safe and effective therapy is increasing all over the world. However, there are many aspects of drugs in making these decisions that are less commonly studied such as the correlation of cardiac output with pharmacokinetics of drugs. The cardiac output, besides the other factors, is also affected by drugs like atenolol. Therefore, th...

متن کامل

Blood glucose increments as a measure of body physiology

The initial distribution volume of glucose (IDVG) can be calculated from the arterial plasma glucose level between 3 and 7 min after a bolus intravenous infusion of 5 g glucose. Ishihara and colleagues have investigated the value of IDVG over the past decade. Although IDVG is simple and cheap to measure, there have been several very different proposals regarding what it should be used for. The ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Current opinion in critical care

دوره 13 3  شماره 

صفحات  -

تاریخ انتشار 2007