Lower incidence of thrombus formation with cryoenergy versus radiofrequency catheter ablation.
نویسندگان
چکیده
BACKGROUND Radiofrequency (RF) catheter ablation is limited by thromboembolic complications. The objective of this study was to compare the incidence and characteristics of thrombi complicating RF and cryoenergy ablation, a novel technology for the catheter-based treatment of arrhythmias. METHODS AND RESULTS Ablation lesions (n=197) were performed in 22 mongrel dogs at right atrial, right ventricular, and left ventricular sites preselected by a randomized factorial design devised to compare RF ablation with cryocatheter configurations of varying sizes (7F and 9F), cooling rates (-1 degrees C/s, -5 degrees C/s, and -20 degrees C/s) and target temperatures (-55 degrees C and -75 degrees C). Animals were pretreated with acetylsalicylic acid and received intraprocedural intravenous unfractionated heparin. Seven days after ablation, the incidence of thrombus formation was significantly higher with RF than with cryoablation (75.8% versus 30.1%, P=0.0005). In a multiple regression model, RF energy remained an independent predictor of thrombus formation compared with cryoenergy (OR, 5.6; 95% CI, 1.7, 18.1; P=0.0042). Thrombus volume was also significantly greater with RF than with cryoablation (median, 2.8 versus 0.0 mm3; P<0.0001). More voluminous thrombi were associated with larger RF lesions, but cryolesion dimensions were not predictive of thrombus size. CONCLUSIONS RF energy is significantly more thrombogenic than cryoenergy, with a higher incidence of thrombus formation and larger thrombus volumes. The extent of hyperthermic tissue injury is positively correlated with thrombus bulk, whereas cryoenergy lesion size does not predict thrombus volume, most likely reflecting intact tissue ultrastructure with endothelial cell preservation.
منابع مشابه
Results of Cryoenergy and Radiofrequency-Based Catheter Ablation for Treating Ventricular Arrhythmias Arising From the Papillary Muscles of the Left Ventricle, Guided by Intracardiac Echocardiography and Image Integration.
BACKGROUND Catheter radiofrequency ablation of ventricular arrhythmias (VAs) arising from the left ventricle's papillary muscles has been associated with inconsistent results. The use of cryoenergy versus radiofrequency has not been compared yet. This study compares outcomes and complications of catheter ablation of VA from the papillary muscles of the left ventricle with either cryoenergy or r...
متن کاملNovel contact force sensor incorporated in irrigated radiofrequency ablation catheter predicts lesion size and incidence of steam pop and thrombus.
BACKGROUND An open-irrigated radiofrequency (RF) ablation catheter was developed to measure contact force (CF). Three optical fibers measure microdeformation of the catheter tip. The purpose of this study was to (1) validate the accuracy of CF sensor (CFS) (bench test); and (2) determine the relationship between CF and tissue temperatures, lesion size, steam pop, and thrombus during RF ablation...
متن کاملCatheter-based ablation of supraventricular tachycardias in a paediatric population – a decade of experience at a single centre
Accessory atrioventricular pathways (AP) and dual AV nodal physiology are common substrates for paroxysmal supraventricular tachycardias (SVT) in children and adolescents. Definitive treatment can be achieved by catheter ablation with either radiofrequency (RF) or cryoenergy. Aim of this study was to assess effectiveness and safety of RFand cryoenergy ablation in a paediatric population. During...
متن کاملPrevention and Treatment of Lower Limb Deep Vein Thrombosis after Radiofrequency Catheter Ablation: Results of a Prospective active controlled Study
We conducted a prospective, single-center, active controlled study from July 2013 to January 2015, in Chinese patients with rapid ventricular arrhythmia who had received radiofrequency catheter ablation (RFCA) treatment to determine formation of lower extremity deep vein thrombosis (LDVT) post RFCA procedure, and evaluated the effect of rivaroxaban on LDVT. Patients with asymptomatic pulmonary ...
متن کاملCatheter cryoablation of atrio-ventricular nodal reentrant tachycardia. A clinical review.
Cryoablation is a new method in interventional cardiac electrophysiology for percutaneous catheter ablation of cardiac arrhythmias. Cryothermal mapping enables the functional assessment of a particular site before permanent ablation. In this way, the targeted tissue may be confirmed as safe for ablation. This is useful in high risk ablation, for example, nex to the His bundle or the compact AV ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation
دوره 107 15 شماره
صفحات -
تاریخ انتشار 2003