Changes in the abutment-implant interface in Morse taper implant connections after mechanical cycling: a pilot study.

نویسندگان

  • Sergio Alexandre Gehrke
  • Frederico de Araújo Pereira
چکیده

PURPOSE The aim of this study was to measure and compare, using scanning electron microscopy, the abutment-implant interface of a Morse taper system before and after cyclic loading. MATERIALS AND METHODS Four Morse cone implants and four solid abutments were used. These abutments had been machined to reduce the diameter of the part corresponding to the site of prosthesis cementation. They were then screwed onto the implants and torqued to 25 N. Under a scanning electron microscope, 32 images (16 before and 16 after cycling) of the interfaces were obtained under ×1,000 and ×5,000 magnification. The samples were subjected to 345,600 cycles with a fatigue testing machine, in which the applied load was 80 N and the frequency was 4 Hz, to simulate chewing. With appropriate software (Image Tool 3.0), the marginal gaps of the interfaces before and after load cycling were measured. The data were analyzed with the Student t test at a significance level of 5%. RESULTS Significant differences were found between interfaces before and after cycling. Prior to mechanical cycling, the Morse taper implant/abutment assemblies exhibited an average gap size of 3.34 ± 2.17 μm, whereas the average gap size after mechanical cycling was 1.35 ± 0.64 μm. CONCLUSION After mechanical cycling, there was a significant decrease in the size of the gap, which indicated better adaptation and sealing ability at the level of the microgap.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preload loss and bacterial penetration on different implant-abutment connection systems.

Preload loss can favor the occurrence of implant-abutment interface misfit, and bacterial colonization at this interface may lead to implant failure. The aim of this study was to evaluate the preload loss and bacterial penetration through the implant-abutment interface of conical and external hexagon connection systems subjected to thermal cycling and mechanical fatigue (TM). Four different imp...

متن کامل

Morse taper dental implants and platform switching: The new paradigm in oral implantology

The aim of this study was to conduct a literature review on the potential benefits with the use of Morse taper dental implant connections associated with small diameter platform switching abutments. A Medline bibliographical search (from 1961 to 2014) was carried out. The following search items were explored: "Bone loss and platform switching," "bone loss and implant-abutment joint," "bone reso...

متن کامل

Abutment fracture and the technique Used to Remove the fracture portion of the Abutmet: Case Report

Abstract This clinical report presents a case of abutment fracture, due to occlusal overload, occurred with an implant-supported restoration on right mandibular first molar of a female patient. After 6 months of prosthetic reconstruction implants, the patient returned to the clinic due to the loss of implant crown. The fractured fragment of the abutment with the screw protec...

متن کامل

Mechanical analysis of conventional and small diameter conical implant abutments

PURPOSE The aim of the present study was to evaluate if a smaller morse taper abutment has a negative effect on the fracture resistance of implant-abutment connections under oblique compressive loads compared to a conventional abutment. MATERIALS AND METHODS Twenty morse taper conventional abutments (4.8 mm diameter) and smaller abutments (3.8 mm diameter) were tightened (20 Ncm) to their res...

متن کامل

Stability of external and internal implant connections after a fatigue test

OBJECTIVE The objective of this study was to compare the torque and detorque values of screw intermediates of external hexagon, internal hexagon, and Morse taper implants in single restorations before and after mechanical cycling. MATERIALS AND METHODS The study sample was divided into three groups (n = 10) as follows: group EH - external hexagon implant, group IH - internal hexagon implant, ...

متن کامل