This experiment was undertaken to investigate whether the half life of the electron capture decay of Ru in a metallic environment shows any temperature dependence, as has been claimed recently for the electron capture decay of Be [1]. Previous publications claiming to observe a temperature dependence of β-decay half-lives [1 3] in a metallic environment have used the so-called “Debye effect” to explain the phenomenon. This Debye-effect theory claims that the conduction electrons, present in a metal, comprise a sort of plasma, referred to as a Debye plasma, which alters the phase space available for beta decay. It is argued that the “Debye plasma” would decrease the phase space for β-decay or electron capture, thus slowing the decay rate and increasing the half-life; and would increase it for β-decay, which would have the opposite effect on the half-life. The theory also indicates that this change in phase space should be enhanced if the sample is cooled to very low temperatures (e.g., ~20 K). We have already demonstrated that this effect does not, in fact, exist in the case of β-decay by measuring the half-life of Au in gold at room temperature and at 20 K [4]. We are now examining the electron-capture decay of Ru in ruthenium. We have already completed the 20-K portion of the measurement. We used a ruthenium disc obtained from Goodfellow Corporation. This was a single crystal, 8 mm in diameter, 1 mm thick, with a purity of 99.999%. The crystal was activated in a flux of ~10 neutrons/cm·s for 10 s irradiation time, at the Texas A&M Triga reactor. For the decay measurement we used the same set-up as we did previously for Au [4]. The activated ruthenium sample containing Ru (and other activities produced from stable ruthenium isotopes) was placed upon the cold head of a CryoTorr 7 cryopump. A 70% HPGe detector was placed directly opposite the sample, and just outside the plate covering the cryopump. A cavity is bored in the cover-plate such that only 3.5 mm of stainless steel remains between the sample and the face of the detector. The detector and cryopump were placed such that the distance between them remained constant throughout the measurement. Consecutive six-hour γ-ray spectra were acquired and saved for a period of 29 days. All these spectra were collected for an identical, pre-set live time. Throughout the experiment, we synchronized the time, prior to each day’s collection, using the signal broadcast from radio station WWVB. We also kept the system’s dead time below about 3% for all but the first few days’ spectra. Since the TRUMP card used in our data collection corrects for dead time losses, our results were nearly independent of dead time losses, but we also made a small additional correction determined empirically [4]. We measured the half-life of Ru via the 216 keV γ-ray in Tc, which follows its β-decay. We used the least-squares peak-fitting program GF3 (in the RADware series [5]), to obtain the peak area in each of the ~115 recorded spectra. Use of this program allowed us to make very accurate determinations of spectral backgrounds and areas. Each peak was analyzed and then corrected for residual, ratedependent effects, as mentioned above. The decay curves resulting from this analysis were then plotted as a function of time and analyzed, by a maximum-likelihood fit (single exponential), using a code based
منابع مشابه
Half - life of the electron - capture decay of 97 Ru : Precision measurement shows no temperature dependence
We have measured the half-life of the electron-capture (ec) decay of 97Ru in a metallic environment, both at low temperature (19 K), and also at room temperature. We find the half-lives at both temperatures to be the same within 0.1%. This demonstrates that a recent claim that the ec decay half-life for 7Be changes by 0.9% ± 0.2% under similar circumstances certainly cannot be generalized to ot...
متن کاملEnhanced electron-capture decay rate of 7Be encapsulated in C60 cages.
The decay rate of 7Be electron capture was measured in C60 and Be metal with a reference method. The half-life of 7Be endohedral C60 ((7)Be@C(60)) and 7Be in Be metal (Be metal (7Be)) is found to be 52.68+/-0.05 and 53.12+/-0.05 days, respectively. This amounts to a 0.83% difference in electron-capture decay half-life between (7)Be@C(60) and Be metal (7Be). Our result is a reflection of the dif...
متن کاملTemperature dependence of continuum and time resolved photoluminescence of germanium nanostructures
Germanium nanostructures were generated in the post annealed germanium oxide thin films. Visible and near infrared photoluminescence bands were observed in the samples annealed at 350°C and 400°C, respectively. These different luminescence ranges are attributed to the presence of the defects in oxide matrix and quantum confinement effect in the germanium nanostructures, respectively. Decay ti...
متن کاملDetermination of Isosorbide Dinitrate in Serum by Gas Chromatography with New Generation of Electron Capture Detector and its Application in Pharmacokinetic Study
Isosorbide dinitrate (ISDN) is an effective drug in treatment of angina pectoris. In this study a new generation of electron capture detector (non-radioactive) with a short, non-polar and wide-bore column was used for analysis of ISDN in human serum. ISDN was extracted from serum by a mixture of ether and ethyl acetate and concentrated at room temperature. The method was linear between 5-50...
متن کاملElectrogenerated Chemiluminescence. 35. Temperature Dependence of the ECL Efficiency of Ru(bpy),*+ in Acetonitrile and Evidence for Very High Excited State Yields from Electron Transfer Reactions
The temperature dependence of the ECL emission yield, @ECL, of Ru(bpy)?+ in acetonitrile has been determined and was found to correlate closely with the luminescence quantum yield, @ e , of the lowest R~(bpy) ,~+ dn* metal-to-ligand charge transfer (MLCT) excited state. Evidence is presented that at low temperatures (< -30 "C) the ECL emission yield becomes equal to the luminescence quantum yie...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2008