چکیده

Affected by the negative sequence component and harmonic component of three-phase grid, the conventional three-phase software phase-locked loop (SPLL) circuits were unable to extract the magnitude-phase information of three-phase fundamental positive sequence component accurately, and the dynamic response speed was slow. In order to solve this problem, this paper introduces T/4 time-lapse elimination detection, a novel method of detecting three-phase magnitude-phase based on double d-q synchronous reference frame, functioning in decoupling positive and negative sequences of fundamental wave. When the voltage (or current) fundamental positive and negative sequence components are separated, the positive sequence component as well as the magnitude and phase position of negative sequence component from three-phase fundamental can be detected, so it is effective to restrain the impact on detection precision from negative sequence component. To verify the performance of this novel method, simulation experiments like transient response under normal grid condition, dynamic response under three-phase unbalance with harmonic pollution condition and dynamic response under phase jump condition are carried out. The simulation results verify that the proposed method overcomes the shortcoming of conventional three-phase phase-locked loop and tracks accurately the magnitudes and phases of the foundational positive-sequence voltage under harmonic pollution condition. And the results also verify that the proposed method can suppress odd harmonic propagation and has a higher detecting precision comparing with T/16 time-lapse elimination method. The improved T/4 time-lapse elimination detection can be wildly applied in three-phase power electronic devices.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sensitivity analysis of time lapse gravity for monitoring fluid saturation changes in a giant multi-phase gas reservoir located in south of Iran

The time lapse gravity method is a widely used technique to monitor the subsurface density changes in time and space. In hydrocarbon reservoirs, the density variations are due to different factors, such as: substitution of fluids with high density contrast, water influx, gas injection, and the variation in reservoir geomechanical behavior. Considering the monitoring of saturation changes in the...

متن کامل

Adaptive Speed Control of Three-Phase Induction Servo-drives Based on Feedback Linearization Theory

In this paper, based on feedback linearization control method and using a special PI (propotational integrator) regulator (IP) in combination with a feed-forward controller, a three-phase induction servo-drive is speed controlled. First, an observer is employed to estimate the rotor d and q axis flux components. Then, two input-output state variables are introduced to control the dynamics of to...

متن کامل

Adaptive Speed Control of Three-Phase Induction Servo-drives Based on Feedback Linearization Theory

In this paper, based on feedback linearization control method and using a special PI (propotational integrator) regulator (IP) in combination with a feed-forward controller, a three-phase induction servo-drive is speed controlled. First, an observer is employed to estimate the rotor d and q axis flux components. Then, two input-output state variables are introduced to control the dynamics of to...

متن کامل

Determination of Organic Sulfur Contaminants Using Hollow Fibre-protected Liquid-phase Micro-extraction Coupled with Gas Chromatography

A simple and solvent-minimized sample preparation technique based on hollow fibre-protected liquid-phase micro-extraction has been developed for extraction of fifteen organic sulphur compounds from aqueous samples. The analysis of the extracted them was performed by gas chromatography equipped with mass spectrometry and/or flame photometric detectors. 3.3 µL of organic solvent located in the lu...

متن کامل

Dynamic anomaly detection by using incremental approximate PCA in AODV-based MANETs

Mobile Ad-hoc Networks (MANETs) by contrast of other networks have more vulnerability because of having nature properties such as dynamic topology and no infrastructure. Therefore, a considerable challenge for these networks, is a method expansion that to be able to specify anomalies with high accuracy at network dynamic topology alternation. In this paper, two methods proposed for dynamic anom...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • JSW

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014