Simultaneous determination of caffeine, theobromine, and theophylline by high-performance liquid chromatography.

نویسندگان

  • Marcia S Bispo
  • Márcia Cristina C Veloso
  • Heloísa Lúcia C Pinheiro
  • Rodolfo F S De Oliveira
  • José Oscar N Reis
  • Jailson B De Andrade
چکیده

This work relates the development of an analytical methodology to simultaneously determine three methylxanthines (caffeine, theobromine, and theophylline) in beverages and urine samples based on reversed-phase high-performance liquid chromatography. Separation is made with a Bondesil C18 column using methanol-water-acetic acid or ethanol-water-acetic acid (20:75:5, v/v/v) as the mobile phase at 0.7 mL/min. Identification is made by absorbance detection at 273 nm. Under optimized conditions, the detection limit of the HPLC method is 0.1 pg/mL for all three methylxanthines. This method is applied to urine and to 25 different beverage samples, which included coffee, tea, chocolate, and coconut water. The concentration ranges determined in the beverages and urine are: < 0.1 pg/mL to 350 microg/mL and 3.21 microg/mL to 71.2 microg/mL for caffeine; < 0.1 pg/mL to 32 microg mL and < 0.1 pg/mL to 13.2 microg/mL for theobromine; < 0.1 pg/mL to 47 microg/mL and < 0.1 pg/mL to 66.3 microg/mL for theophylline. The method proposed in this study is rapid and suitable for the simultaneous quantitation of methylxanthines in beverages and human urine samples and requires no extraction step or derivatization.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous HPLC determination of caffeine, theobromine, and theophylline in food, drinks, and herbal products.

A rapid and selective high-performance liquid chromatographic (HPLC) method is developed for the separation and determination of caffeine, theobromine, and theophylline. The chromatography is performed on a Zorbax Eclipse XDB-C8 column (4.6x150 mm i.d., 5-microm particle size) at 25 degrees C, with a mobile phase of water-THF (0.1% THF in water, pH 8)-acetonitrile (90:10, v/v). The flow rate is...

متن کامل

Simultaneous determination of caffeine, theobromine and theophylline in foods and pharmaceutical preparations by using ion chromatography

Two ion chromatographic methods have been proposed for the simultaneous determination of caffeine, theobromine and theophylline. The separations were based on isocratic elutions and the determinations on ultraviolet absorbance detections at 274 nm. The detection limits (signal-to-noise ratio 3:1) for the three compounds were all below sub-mg mlÿ1 level. The methods have been successfully applie...

متن کامل

Simultaneous determination of caffeine and theobromine in local area coffee brews

The concentrations of caffeine and theobromine were determined using the method of external standards and high-performance liquid chromatography (HPLC). House brews from Atomic Coffee, Babs, Coffee Stop (Caribou Coffee), Dunn Bros., Concordia’s Maize (Minnesota Mudd and Nicaraguan), Moxie Java, and Starbucks were collected and analyzed. Dunn Bros. reported the highest amount of caffeine per oun...

متن کامل

استفاده از سلول های در حال استراحت سویه ی بومی غربال گری شده Rhodotorula sp. CW03 در بیوترانسفورماسیون کافئین به تئوفیلین و پاراگزانتین

Introduction & Objective: In recent years, microorganisms have been applied as biocatalysts for making pharmaceutically natural products. Microbial biotransformation of caffeine suggests a dual approach for biodegradation of toxic caffeine from polluted environments and a method for the production of medically and pharmaceutically valuable dimethylxanthines. The present work describes the ident...

متن کامل

Simultaneous Determination of Biogenic Amines and Methylxanthines in Foodstuff—Sample Preparation with HPLC-DAD-FL Analysis

Chromatographic system for simultaneous determination of levodopa, biogenic amines, and methylxanthines in food has been developed. Chromatographic column and precolumn with octadecylsilane phase and simultaneously fluorescence and DAD detectors have been used. Gradient elution with acetate buffer (pH=4.66) with acetonitrile has been applied. Examination included levodopa, norepinephrine, dopam...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of chromatographic science

دوره 40 1  شماره 

صفحات  -

تاریخ انتشار 2002