Reproducibility of pixel values for two photostimulable phosphor plates in consecutive standardized scannings Reprodutibilidade dos valores de “pixels” de duas placas de fósforo fotoestimuláveis em leituras padronizadas consecutivas
نویسندگان
چکیده
The objective of the present study was to determine the reproducibility of the pixel values obtained with the Digora system (Soredex, Finland). Exposures were standardized, with variation in exposure and scanning time of two photostimulable phosphor plates containing a stepwedge image. The smallest variation in pixel values ranged from 50 to 75%, with the widest variations being observed in less dense steps. A signifi cant difference in pixel values was observed in terms of X-ray exposure and scanning times and between the two plates themselves (ANOVA, p < 0.01). Using the present methodology, the reproducibility of pixel values was not satisfactory for the tested white photostimulable plates. This wide variation in digitalization might be infl uenced by the amount of X-rays that sensitized the plates. It may be important to establish the reproducibility of the pixel values in quantitative studies using digital image. DESCRIPTORS: Radiography, dental, digital; Reproducibility of results. RESUMO: O objetivo do presente trabalho foi determinar a reprodutibilidade dos valores de “pixels” obtidos com o sistema Digora (Soredex, Finlândia). As exposições foram padronizadas, com variação no tempo de exposição e leitura de duas placas de fósforo fotoestimuláveis contendo a imagem de um penetrômetro. A menor variação nos valores de “pixels” foi de 50 a 75%, sendo as maiores variações oriundas nas faixas mais claras. Uma diferença signifi cante nos valores de “pixels” foi observada em relação ao tempo de exposição e leitura das placas e entre as duas placas (ANOVA, p < 0,01). Utilizando a presente metodologia, a reprodutibilidade dos valores de “pixels” das placas testadas do sistema Digora não foi satisfatória. Essa grande variação na digitalização pode ter sido infl uenciada pela quantidade de Raios X que sensibilizou as placas. Isso pode ser importante para estabelecer a reprodutibilidade dos valores de “pixels” em estudos quantitativos usando imagem digital. DESCRITORES: Radiografi a dentária digital; Reprodutibilidade dos resultados.
منابع مشابه
Short version of the Depression Anxiety Stress Scale-21: is it valid for Brazilian adolescents?
Objective To evaluate the interday reproducibility, agreement and validity of the construct of short version of the Depression Anxiety Stress Scale-21 applied to adolescents. Methods The sample consisted of adolescents of both sexes, aged between 10 and 19 years, who were recruited from schools and sports centers. The validity of the construct was performed by exploratory factor analysis, and...
متن کاملRetention of Copper(II) Metal Ions in a Silicon-Glass Microfluidic Device
Neste trabalho é descrita a construção de um microssistema em silício para retenção de íons cobre(II). Processo fotolitográfico convencional foi empregado para transferir o padrão de microcanais para o substrato de silício. Utilizando corrosão por íons reativos (RIE) com plasma de SF6, foram produzidos canais de 50 μm de largura e 10 μm de profundidade. Os canais foram selados com vidro de boro...
متن کاملViability of gait speed test in hospitalized elderly patients.
OBJECTIVE The gait speed test (GST) is a physical test that can predict falls and aid in the diagnosis of sarcopenia in the elderly. However, to our knowledge, there have been no studies evaluating its reproducibility in hospitalized elderly patients. The objective of this study was to evaluate the safety and reproducibility of the six-meter GST (6GST) in hospitalized elderly patients. METHOD...
متن کاملMeasurement of the optical density of packable composites – comparison between direct and indirect digital systems Mensuração da densidade óptica de compósitos compactáveis – comparação entre sistemas digitais direto e indireto
The aim of this study was to me a su re the op ti cal den sity of four pac ka ble com po si te re sins with widths of 1, 2, 3 and 4 mm, by me ans of Di go ra® (di rect) and Dent Scan Dent Vi ew® (in di rect) di gi tal ima ging systems, in or der to com pa re both methods. Twenty acr ylic pla tes, with the pro po sed thick nes ses, were used, each one con ta i ning a sam ple of each re sin. Each...
متن کاملQuantitative Structure-Activity Relationships (QSAR) of 4-Amino-2,6-diarylpyrimidine- 5-carbonitriles with Anti-inflammatory Activity
As atividades antiinflamatórias de oito compostos 4-amino-2,6-diarilpirimidina-5-carbonitrilas foram sujeitas a uma análise QSAR baseada nos resultados de cálculos de estrutura eletrônica B3LYP/6-31G(d,p) e AM1. Análise de Componentes Principais e regressões baseados nesses dados indicam que compostos potencialmente mais ativos teriam menores valores de momentos de dipolo e de coeficientes de p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2006