Reply to "Interlaboratory and interstudy reproducibility of a novel lateral-flow device: a statistical issue".
نویسندگان
چکیده
Iwas interested to read the paper by N. P. Wiederhold and colleagues published in the November 2012 issue of the Journal of Clinical Microbiology (1). The authors aimed to determine interlaboratory and interstudy reproducibility as well as to assess the effect of antifungal therapy on a lateral-flow device (LFD) developed for invasive pulmonary aspergillosis (IPA) detection. They reported a good interlaboratory agreement (LFD result agreement, 97% [32/33] of the serum and 78.8% [26/33] of the BAL samples from infected animals) and a good interstudy agreement (1). Such a descriptive result has nothing to do with reliability and actually is one of the common mistakes in reliability analysis (2–6). Moreover, Wiederhold et al. reported that the serum sensitivity of each surrogate marker assay was reduced in animals treated with antifungals. In contrast, the markers remained elevated within the BAL fluids of treated animals, demonstrating that the results of the LFD assay are reproducible between different laboratories and studies (1). Sensitivity is one of the seven well-known statistical estimates for validity (diagnostic accuracy) analysis and should not be used for reliability purposes (2–6). Why did the authors not use well-known intraclass correlation coefficient (ICC) or weighted kappa values to assess reliability (2–6)? Reliability and validity are two completely different methodological issues in research. Sensitivity, specificity, positive predictive values, negative predictive values, likelihood ratios of positive results (true positive/false positive), and likelihood ratios of negative results (false negative/true negative) as well as odds ratios (true results false results, preferably more than 50) and diagnostic accuracy are among the tests to evaluate the validity (accuracy) of a single test compared with a gold standard (5, 6). As a take-home message, for reliability and validity, appropriate statistical tests should be applied.
منابع مشابه
Correction: reproducibility of in-vivo diffusion tensor cardiovascular magnetic resonance in hypertrophic cardiomyopathy
BACKGROUND Myocardial disarray is an important histological feature of hypertrophic cardiomyopathy (HCM) which has been studied post-mortem, but its in-vivo prevalence and extent is unknown. Cardiac Diffusion Tensor Imaging (cDTI) provides information on mean intravoxel myocyte orientation and potentially myocardial disarray. Recent technical advances have improved in-vivo cDTI, and the aim of ...
متن کاملSecond-generation optical coherence tomography in clinical practice. High-speed data acquisition is highly reproducible in patients undergoing percutaneous coronary intervention.
INTRODUCTION AND OBJECTIVES The development of second-generation optical coherence tomography (i.e. Fourier domain optical coherence tomography, FD-OCT) has made it possible to perform high speed pullbacks during image acquisition without the need for transient occlusion of the coronary artery. The objective of this study was to assess the reproducibility of FD-OCT systems for characterizing pl...
متن کاملNumerical Study of Droplet Generation Process in a Microfluidic Flow Focusing
Microfluidic flow focusing devices have been utilized for droplet generation on account of its superior control over droplet size. Droplet based microfluidics addressed many scientific issues by providing a novel technological platform for applications such as biology, pharmaceutical industry, biomedical studies and drug delivery. This study numerically investigated the droplet generation proce...
متن کاملInterstudy reproducibility of three-dimensional volume-selective fast spin echo magnetic resonance for quantifying carotid artery wall volume.
PURPOSE To assess the interstudy reproducibility of a three-dimensional volume-selective, fast spin echo (FSE) magnetic resonance technique for the assessment of carotid artery wall volume, which is a marker for total carotid plaque volume. MATERIALS AND METHODS Interstudy reproducibility was evaluated in 10 subjects with evidence of carotid artery atherosclerotic disease on carotid Doppler u...
متن کاملMulti-center transferability of a breath-hold T2 technique for myocardial iron assessment
BACKGROUND Cardiac iron overload is the leading cause of death in thalassemia major and is usually assessed using myocardial T2* measurements. Recently a cardiovascular magnetic resonance (CMR) breath-hold T2 sequence has been developed as a possible alternative. This cardiac T2 technique has good interstudy reproducibility, but its transferability to different centres has not yet been investig...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of clinical microbiology
دوره 51 5 شماره
صفحات -
تاریخ انتشار 2013