Effect of different concentrations of papain gel on orthodontic bracket bonding
نویسندگان
چکیده
BACKGROUND The objective of this study was to verify the hypothesis that enamel deproteinization with papain gel at concentrations of 2%, 4%, 6%, 8%, and 10% increases shear bond strength as concentration increases. METHODS A total of 180 bovine mandibular permanent incisors were used, divided into six groups (n=30), and denominated as follows: group 1 is the control group (CG) in which brackets are bonded with resin-modified glass ionomer cement (RMGIC) according to the manufacturer's recommendations and groups 2, 3, 4, 5, and 6 have brackets bonded with RMGIC after enamel deproteinization with papain gel at concentrations of 2%, 4%, 6%, 8%, and 10%, respectively. After bonding, teeth were immersed in artificial saliva and kept at a temperature of 37°C for 24 h. Mechanical tests were then performed in a universal mechanical test machine EMIC DL 5000 (Sao Jose dos Pinhais, Brazil). Values obtained were submitted to analysis of variance and then to Tukey's test (p<0.05). RESULTS The results demonstrated that groups 5 and 6 showed the highest shear bond strength, differing statistically from the other groups (p<0.05). CG with no papain gel used showed the lowest value and in turn showed no differences for groups 2, 3, and 4. As regards adhesive remnant index, CG showed statistical differences from the others. Groups 2, 3, 4, 5, and 6, in which papain gel was used, presented no statistical differences among them (p>0.05). CONCLUSIONS It was concluded that enamel deproteinization with 8% and 10% papain gel increases shear bond strength of orthodontic brackets bonded with RMGIC.
منابع مشابه
Microleakage under Orthodontic Metal Brackets Bonded with Three Different Bonding Techniques with/without Thermocycling
Introduction: The aim of this study was to compare the microleakage of beneath the orthodontic brackets bonded with 3 different bonding techniques and evaluate the effect of thermocycling. Methods: One hundred and twenty premolars were randomly divided into 6 groups, received the following treatment: group 1: 37% phosphoric acid gel+Unite primer+Unite adhesive, group 2: 37% phosphoric acid gel+...
متن کاملEffects of Light-cured versus No-mix and Self-etch Primer Adhesives on Enamel Discoloration following Orthodontic Bracket Bonding
Introdouction: According to the importance of enamel discoloration and controversy regarding the effect of different orthodontic bonding materials on tooth discoloration, the aim of this study was to determine enamel discoloration following orthodontic brackets using different bonding materials. Materials and methods: This in-vitro study, 30 recently extracted human premolars with inta...
متن کاملComparison between self-etching and conventional primers in repeated bracket bonding
Background and Aim: This study aimed to evaluate the effect of repeated bonding by self-etching primers (SEPs) and a conventional phosphoric acid-etchant on shear bond strength (SBS), adhesive remnant index (ARI), and enamel morphology at different debonding time points. Materials and Methods: In this experimental study, 120 premolars were randomly divided into six groups of 20. In the first t...
متن کاملEffect of Incorporation of Nano-Hydroxyapatite and Nano-Zinc Oxide in Resin Modified Glass Ionomer Cement on Metal Bracket Debonding
Background and Aim: Use of fluoride releasing materials to decrease the risk of demine-ralization around orthodontic brackets would be reasonable as an adhesive for bracket bonding only if they provide acceptable shear bond strength (SBS). The aim of this study was to evaluate the SBS of resin-modified glass ionomer cements (RMGICs) modified by nano-zinc oxide (NZnO) and nano- hydroxyapatite (N...
متن کاملGalvanic Corrosion among Different Combination of Orthodontic Archwires and Stainless Steel Brackets
Introduction: The aim of this study was to assess the galvanic behavior of different bracket and archwire combinations that are commonly used in orthodontic treatments. Methods: Three types of orthodontic archwires with a diameter of 0.016×0.022 inch and 80 standard edgewise maxillary central incisor brackets were selected. Three groups consisted of different wire-bracket couples and one group ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 14 شماره
صفحات -