Radiolucencies surrounding acetabular components with three-dimensional coatings: artifact or real?

نویسندگان

  • Ahmad Faizan
  • Philip Chuang
  • Carlos Aponte
  • Vincent Moretti
  • Peter F. Sharkey
چکیده

Background Several 2-dimensional and 3-dimensional surfaces are available for cementless acetabular fixation. Plain radiographs are used to assess osseointegration; however, the radiographs are limited by their inability to capture the bone fixation process occurring over the 3-dimensional cup surface. In this cadaveric study, we compared the bone apposition between 2-dimensional and 3-dimensional cups. Methods Both types of cups were implanted in 6 cadavers and pelvic radiographs obtained. Each cup was resected from the pelvis with adequate bone around it, and subsequently embedded in a polymer. Six sections of each cup were obtained to examine the metal and bone interface. Photographs and contact radiograph images were obtained for each section, and these were graded to arrive at percent metal-bone contact values for the cups. Results On average, <30% of the cups' areas displayed radiolucencies on the pelvic radiographs for both cup types. For the section images and radiographs, there was about 80% aggregate contact between the cups and surrounding bone in both cup types. In the 3-dimensional cups group, some inconsistencies were found between the section photographs and the corresponding radiograph images. The radiolucencies observed on the section radiograph could not always be correlated with metal to bone gap on the section photograph. Conclusions Good metal-bone contact (75% + contact area) was observed on both cup types. The inconsistencies found in the 3-dimensional cup group may be because of the interaction of radiographs with the unique porous cup surface resulting in artifactual radiolucencies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of cementless cup surface on stability and bone fixation 2 years after total hip arthroplasty.

Loss of fixation between bone and implant surface is one of the main treatment problems in total hip arthroplasty. It might lead to implant instability, bone loss and treatment failure resulting in revision surgery. Surface modification is a method for improving bone response to implant and increasing implant osseointegration. However, the currently applied modifications such as hydroxyapatite ...

متن کامل

Importance of Preoperative Imaging in Acetabular Revision Surgery - A Case Report

Acetabular defects, particularly as a result of protrusion of acetabular components into the hemipelvis, may cause serious complications during revision procedures as a result of iatrogenic injury to surrounding anatomical structures. In these challenging cases, we advocate the utilisation of preoperative three dimensional imaging. MRI and CT- imaging offer superior understanding of the three-d...

متن کامل

Cemented polyethylene and cementless porous-coated acetabular components have similar outcomes at a mean of seven years after total hip replacement: a prospective randomised study.

The aim of this prospective randomised study was to compare the clinical and radiological results of a cemented all-polyethylene Ultima acetabular component with those of a cementless porous-coated acetabular component (PFC) following total hip replacement (THR). A total of 287 patients received either a polyethylene acetabular component (group A) or a cobalt-chromium porous-coated co...

متن کامل

Three-dimensional printing model improves morphological understanding in acetabular fracture learning: A multicenter, randomized, controlled study

Conventional education results in unsatisfactory morphological understanding of acetabular fractures due to lack of three-dimensional (3D) details and tactile feedback of real fractures. Virtual reality (VR) and 3D printing (3DP) techniques are widely applied in teaching. The purpose of this study was to identify the effect of physical model (PM), VR and 3DP models in education of morphological...

متن کامل

Revisions of Extensive Acetabular Defects with Impaction Grafting and a Cement Cup

BACKGROUND Loosening of acetabular components often leads to bony defects. Management of extensive acetabular bone loss in hip revision arthroplasty can be a tremendous challenge. QUESTIONS/PURPOSES We asked whether a reconstruction with impacted bone grafts will provide a durable and pain-free function in extensive acetabular defects. We specifically determined the (1) survival rates with th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2017