Improved assessment of coronary stenosis severity using the relative flow velocity reserve.

نویسندگان

  • D Baumgart
  • M Haude
  • G Goerge
  • J Ge
  • S Vetter
  • N Dagres
  • G Heusch
  • R Erbel
چکیده

BACKGROUND Myocardial fractional flow reserve (FFR) is based on pressure measurements. We have now sought to establish a Doppler-based concept of relative flow velocity reserve (RFVR) for the functional assessment of stenosis severity in epicardial coronary arteries. A clear threshold value to discriminate the functional severity of a coronary stenosis does not exist for coronary flow velocity reserve (CVR) based on intracoronary Doppler measurements. In contrast, the concept of FFR, which is based on intracoronary pressure measurements, has been extensively validated. An FFR value below 0.75 reliably indicates a significant stenosis. METHODS AND RESULTS RFVR is calculated as the ratio between distal CVR in the stenosed target vessel and distal CVR in a nonstenotic reference vessel. In 21 patients, RFVR was determined in 24 target vessels by use of intracoronary adenosine and correlated to the FFR, determined as the ratio of mean poststenotic to aortic pressures, in the target vessel. Stenosis severity was classified according to quantitative coronary angiography analysis. Reference diameter was 3.0+/-0.4 mm (mean+/-SD), and area stenosis was 74+/-15% (range, 40% to 95%). CVRs in the target and reference vessels were 2.1+/-0.5 and 2.6+/-0.7, respectively. FFR ranged from 0.49 to 0.99 (mean, 0.81+/-0.15) and RFVR from 0.53 to 1.0 (mean, 0.82+/-0.13). Poststenotic CVR did not correlate with either percent area stenosis (r=0.27, P=NS) or FFR (r=0.33, P=NS). In contrast, FFR as well as RFVR showed a curvilinear relation to percent area stenosis (r=0.89, P<0.0001 and r=0.79, P<0.0001, respectively). There was a close linear correlation between FFR and RFVR (r=0.91, P<0.0001). CONCLUSIONS RFVR correlates closely to FFR and to percent area stenosis, whereas the correlation of CVR with FFR and percent area stenosis is rather poor. RFVR is a promising new concept for assessment of coronary stenosis severity and clinical decision making based on Doppler measurements.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Utilization of translesional hemodynamics: comparison of pressure and flow methods in stenosis assessment in patients with coronary artery disease.

Aim of this study is the assessment of feasibility and clinical usefulness of a new index of stenosis severity, the slope of the instantaneous transstenotic pressure gradient/velocity relationship. Twenty-one patients scheduled for percutaneous revascularization procedures were studied with simultaneous measurement of poststenotic coronary pressure and flow velocity, in basal condition and duri...

متن کامل

Diagnostic accuracy of combined intracoronary pressure and flow velocity information during baseline conditions: adenosine-free assessment of functional coronary lesion severity.

BACKGROUND The assessment of functional coronary lesion severity using intracoronary physiological parameters such as coronary flow velocity reserve and the more widely used fractional flow reserve relies critically on the establishment of maximal hyperemia. We evaluated the diagnostic accuracy of the stenosis resistance index during nonhyperemic conditions, baseline stenosis resistance index, ...

متن کامل

Noninvasive quantification of coronary blood flow reserve in humans using myocardial contrast echocardiography.

BACKGROUND We hypothesized that coronary blood flow (CBF) reserve could be quantified noninvasively in humans using myocardial contrast echocardiography (MCE). METHODS AND RESULTS Eleven patients with normal epicardial coronary arteries (group I) and 19 with single-vessel coronary stenosis (group II) underwent quantitative coronary angiography, MCE, and CBF velocity measurements at rest and d...

متن کامل

Relative coronary flow velocity reserve improves correlation with stress myocardial perfusion imaging in assessment of coronary artery stenoses.

STUDY OBJECTIVE To evaluate the angiographic and coronary flow velocity parameters that best correlate with the results of stress myocardial perfusion imaging. DESIGN Criterion standard. SETTING Tertiary care center. PATIENTS Forty-eight patients undergoing diagnostic coronary angiography for angina or silent ischemia. INTERVENTIONS We performed angiographic and coronary flow velocity m...

متن کامل

Functional assessment of coronary stenosis: it does make sense, but why don't I do it more often?

and at 6 months follow-up. As in other studies, there was only moderate correlation between coronary flow velocity reserve and diameter stenosis in lesions of moderate severity and the cut-off of coronary flow velocity reserve was 1·9 for patients with intermediate lesions. There are some known limitations with the use of Doppler coronary flow velocity reserve determinations. To obtain a good s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 98 1  شماره 

صفحات  -

تاریخ انتشار 1998