Subzone based magnetic resonance elastography using a Rayleigh damped material model.

نویسندگان

  • Elijah E W Van Houten
  • D vR Viviers
  • M D J McGarry
  • P R Perriñez
  • I I Perreard
  • J B Weaver
  • K D Paulsen
چکیده

PURPOSE Recently, the attenuating behavior of soft tissue has been addressed in magnetic resonance elastography by the inclusion of a damping mechanism in the methods used to reconstruct the resulting mechanical property image. To date, this mechanism has been based on a viscoelastic model for material behavior. Rayleigh, or proportional, damping provides a more generalized model for elastic energy attenuation that uses two parameters to characterize contributions proportional to elastic and inertial forces. In the case of time-harmonic vibration, these two parameters lead to both the elastic modulus and the density being complex valued (as opposed to the case of pure viscoelasticity, where only the elastic modulus is complex valued). METHODS This article presents a description of Rayleigh damping in the time-harmonic case, discussing the differences between this model and the viscoelastic damping models. In addition, the results from a subzone based Rayleigh damped elastography study of gelatin and tofu phantoms are discussed, along with preliminary results from in vivo breast data. RESULTS Both the phantom and the tissue studies presented here indicate a change in the Rayleigh damping structure, described as Rayleigh composition, between different material types, with tofu and healthy tissue showing lower Rayleigh composition values than gelatin or cancerous tissue. CONCLUSIONS It is possible that Rayleigh damping elastography and the concomitant Rayleigh composition images provide a mechanism for differentiating tissue structure in addition to measuring elastic stiffness and attenuation. Such information could be valuable in the use of Rayleigh damped magnetic resonance elastography as a diagnostic imaging tool.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Dual-Stage Reconstruction Algorithm for Magnetic Resonance Elastography

METHODS Spin echo encoded, steady-state harmonic motion data was collected from a cylindrical, gelatine phantom containing multiple inclusions in order to test a dual-stage Magnetic Resonance Elastography (MRE) reconstruction approach. This reconstruction method uses a viscoelastic shear modulus distribution calculated from derivatives of filtered displacement values as an initial guess for an ...

متن کامل

Direct, Fast Estimation of Complex-valued Stiffness for Magnetic Resonance Elastography

Introduction: Constructing images where contrast depends on material hardness has long been a goal of diagnostic imaging. Since the introduction of a phase-based method for dynamically measuring the vectordisplacement of an object in harmonic mechanical motion [1], several authors have introduced methods for obtaining an estimate of material hardness from these data. The local frequency estimat...

متن کامل

Non-identifiability of the Rayleigh damping material model in magnetic resonance elastography.

Magnetic Resonance Elastography (MRE) is an emerging imaging modality for quantifying soft tissue elasticity deduced from displacement measurements within the tissue obtained by phase sensitive Magnetic Resonance Imaging (MRI) techniques. MRE has potential to detect a range of pathologies, diseases and cancer formations, especially tumors. The mechanical model commonly used in MRE is linear vis...

متن کامل

A numerical framework for interstitial fluid pressure imaging in poroelastic MRE

A numerical framework for interstitial fluid pressure imaging (IFPI) in biphasic materials is investigated based on three-dimensional nonlinear finite element poroelastic inversion. The objective is to reconstruct the time-harmonic pore-pressure field from tissue excitation in addition to the elastic parameters commonly associated with magnetic resonance elastography (MRE). The unknown pressure...

متن کامل

Parametric-based brain Magnetic Resonance Elastography using a Rayleigh damping material model

The three-parameter Rayleigh damping (RD) model applied to time-harmonic Magnetic Resonance Elastography (MRE) has potential to better characterise fluid-saturated tissue systems. However, it is not uniquely identifiable at a single frequency. One solution to this problem involves simultaneous inverse problem solution of multiple input frequencies over a broad range. As data is often limited, a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 38 4  شماره 

صفحات  -

تاریخ انتشار 2011