Pulmonary deposition of a nebulised aerosol during mechanical ventilation.

نویسندگان

  • S H Thomas
  • M J O'Doherty
  • H M Fidler
  • C J Page
  • D F Treacher
  • T O Nunan
چکیده

BACKGROUND There is increasing use of therapeutic aerosols in patients undergoing mechanical ventilation. Few studies have measured aerosol delivery to the lungs under these conditions with adequate experimental methods. Hence this study was performed to measure pulmonary aerosol deposition and to determine the reproducibility of the method of measurement during mechanical ventilation. METHODS Nine male patients were studied during mechanical ventilation after open heart surgery and two experiments were performed in each to determine the reproducibility of the method. A solution of technetium-99m labelled human serum albumin (99mTc HSA (50 micrograms); activity in experiment 1, 74 MBq; in experiment 2, 185 MBq) in 3 ml saline was administered with a Siemens Servo 945 nebuliser system (high setting) and a System 22 Acorn nebuliser unit. Pulmonary deposition was quantified by means of a gamma camera and corrections derived from lung phantom studies. RESULTS Pulmonary aerosol deposition was completed in 22 (SD 4) minutes. Total pulmonary deposition (% nebuliser dose (SD)) was 2.2 (0.8)% with 1.5% and 0.7% depositing in the right and left lungs respectively; 0.9% of the nebuliser activity was detected in the endotracheal tube or trachea and 51% was retained within the nebuliser unit. Considerable variability between subjects was found for total deposition (coefficient of variation (CV) 46%), but within subject reproducibility was good (CV 15%). CONCLUSIONS Administration of aerosol in this way is inefficient and further research is needed to find more effective alternatives in patients who require mechanical respiratory support. This method of measurement seems suitable for the assessment of new methods of aerosol delivery in these patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of a spacer on pulmonary aerosol deposition from a jet nebuliser during mechanical ventilation.

BACKGROUND Several factors have been identified which improve nebulised aerosol delivery in vitro. One of these is the addition of a spacer to the ventilator circuit which improves aerosol delivery from a jet nebuliser to a model lung by approximately 30%. The current study was designed to demonstrate whether similar improvements could be demonstrated in vivo. METHODS Ten patients (seven men)...

متن کامل

Aerosol delivery with two ventilation modes during mechanical ventilation: a randomized study

BACKGROUND Volume-controlled ventilation has been suggested to optimize lung deposition during nebulization although promoting spontaneous ventilation is targeted to avoid ventilator-induced diaphragmatic dysfunction. Comparing topographic aerosol lung deposition during volume-controlled ventilation and spontaneous ventilation in pressure support has never been performed. The aim of this study ...

متن کامل

High impact aerosol technology offers higher efficiency, but is not ready for prime time.

The therapeutic administration of medical aerosols has been a standard adjunct to treatment of critically ill patients since positive-pressure mechanical ventilators were introduced over 60 years ago, and most ventilators can operate a jet nebulizer in synchrony with mechanically delivered breaths. However, for the first 40 years, little was known about the efficiency of aerosol delivery during...

متن کامل

Aerosol delivery during mechanical ventilation: from basic techniques to new devices.

Pressurized metered-dose inhalers (pMDIs) and nebulizers are routinely employed for aerosol delivery in mechanically ventilated patients. A significant proportion of the aerosol deposits in the ventilator circuit and artificial airway, thereby reducing the inhaled drug mass. Factors influencing aerosol delivery during mechanical ventilation differ from those in spontaneously breathing patients....

متن کامل

Optimized aerosol delivery to a mechanically ventilated rodent.

BACKGROUND Aerosol delivery through an endotracheal tube during mechanical ventilation of small animals, simulating neonates and small infants, has shown to be influenced by a variety of factors including aerosol generator type, droplet/particle size, ventilator circuitry and ventilation regime. A review of the literature indicates that reported aerosol deposition rates in rodents are quite low...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Thorax

دوره 48 2  شماره 

صفحات  -

تاریخ انتشار 1993