Effective of Inhaling Patterns on Aerosol Drug Delivery :cfd Simulation

نویسندگان

  • Jinho Kim
  • Jim S. Chen
چکیده

Inhaled Pharmaceutical Aerosols (IPAs) delivery has great potential in treatment of a variety of respiratory diseases, including asthma, pulmonary diseases, and allergies. Aerosol delivery has many advantages. It delivers medication directly to where it is needed and it is effective in much lower doses than required for oral administration. Currently, there are several types of IPA delivery systems, including pressurized metered dose inhaler (pMDI), the dry powder inhaler (DPI), and the medical nebulizer. IPAs should be delivered deep into the respiratory system where the drug substance can be absorbed into blood through the capillaries via the alveoli. Researchers have proved that most aerosol particles with aerodynamic diameter of about 1-5 μm, if slowly and deeply inhaled, could be deposited in the peripheral regions that are rich in alveoli [1-3]. The purpose of this study is to investigate the effects of various inhaling rates with breath-holding pause on the aerosol deposition (Dp=0.5-5 μm) in a human upper airway model extending from mouth to 3rd generation of trachea. The oral airway model is three dimensional and non-planar configurations. The dimensions of the model are adapted from a human cast. The air flow is assumed to be unsteady, laminar, and incompressible. The investigation is carried out by Computational Fluid Dynamics (CFD) using the software Fluent 6.2. The user-defined function (UDF) is employed to simulate the cyclic inspiratory flows for different IPA inhalation patterns. When an aerosol particle enters the mouth respiratory tract, its particles experience abrupt changes in direction. The secondary flow changes its direction as the airflow passes curvature. Intensity of the secondary flow is strong after first bend at pharynx and becomes weaker after larynx. In flow separation, a particle can be trapped and follow the eddy and deposit on the surface. Particle deposition fraction generally increases as particle size and inhaling airflow velocity increase.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The use of computational fluid dynamics in inhaler design.

INTRODUCTION Computational fluid dynamics (CFD) has recently seen increased use in the design of pharmaceutical inhalers. The use of CFD in the design of inhalers is made difficult by the complex nature of aerosol generation. At present, CFD has provided valuable insight into certain aspects of inhaler performance, though limitations in computational power have prevented the full implementation...

متن کامل

Regional Ventilation and Aerosol Deposition with Helium-Oxygen in Bronchoconstricted Asthmatic Lungs.

BACKGROUND Theoretical models suggest that He-O2 as carrier gas may lead to more homogeneous ventilation and aerosol deposition than air. However, these effects have not been clinically consistent and it is unclear why subjects may or may not respond to the therapy. Here we present 3D-imaging data of aerosol deposition and ventilation distributions from subjects with asthma inhaling He-O2 as ca...

متن کامل

Inhaled Aerosol Distribution in Human Airways: A Scintigraphy-Guided Study in a 3D Printed Model.

BACKGROUND While it is generally accepted that inertial impaction will lead to particle loss as aerosol is being carried into the pulmonary airways, most predictive aerosol deposition models adopt the hypothesis that the inhaled particles that remain airborne will distribute according to the gas flow distribution between airways downstream. METHODS Using a 3D printed cast of human airways, we...

متن کامل

CFD simulations of enhanced condensational growth (ECG) applied to respiratory drug delivery with comparisons to in vitro data.

Enhanced condensational growth (ECG) is a newly proposed concept for respiratory drug delivery in which a submicrometer aerosol is inhaled in combination with saturated or supersaturated water vapor. The initially small aerosol size provides for very low extrathoracic deposition, whereas condensation onto droplets in vivo results in size increase and improved lung retention. The objective of th...

متن کامل

In silico models of aerosol delivery to the respiratory tract - development and applications.

This review discusses the application of computational models to simulate the transport and deposition of inhaled pharmaceutical aerosols from the site of particle or droplet formation to deposition within the respiratory tract. Traditional one-dimensional (1-D) whole-lung models are discussed briefly followed by a more in-depth review of three-dimensional (3-D) computational fluid dynamics (CF...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008